Anatomical Measurement of Normal Korean Proximal Femur Using Plain Radiography: A Problem when using Proximal Femoral Nail Anti-rotation

Jong Seok Park, W. Kim, Jaewan Soh, Byung-Woong Jang, Tae-Heon Kim, Y. Suh
{"title":"Anatomical Measurement of Normal Korean Proximal Femur Using Plain Radiography: A Problem when using Proximal Femoral Nail Anti-rotation","authors":"Jong Seok Park, W. Kim, Jaewan Soh, Byung-Woong Jang, Tae-Heon Kim, Y. Suh","doi":"10.5371/JKHS.2011.23.4.303","DOIUrl":null,"url":null,"abstract":"Purpose: We propose to improve the use of Proximal Femoral Nail Anti-rotation in Korea by reporting anatomical measurements of the normal Korean proximal femur. Materials and Methods: A total of 230 patients were enrolled who had all experienced a femoral intertrochanteric fracture and undergone the Proximal Femoral Nail Anti-rotation surgical procedure between February 2007 and April 2011. We measured the neck-shaft angle and endosteal width at the isthmus of a normal femur, and the distance between the greater trochanter and the nail tip of the Proximal Femoral Nail Anti-rotation in post-operative plain radiography. We analyzed the average and standard deviations of the measurements. We also investigated correlations with the patient gender. Results: The average neck-shaft angle and endosteal width at the isthmus were 129.7。(111.0~138.3。 ) and 14.5 mm (9.7~23.1 mm), respectively. The average protruded nail length was 4.9 mm (1.0~15.0 mm). The femur neck-shaft angle had a correlation ratio with gender (p=0.000). However, the endosteal width at the isthmus level and the protruded nail length had no correlation ratio with gender (p=0.108, 0.573, respectively). Conclusion: Until now, in intertrochanteric fracture operations using Proximal Femoral Nail Anti-rotation, the selection of devices has been extremely limited. Through this study we present the average Korean anatomical neckshaft angle, endosteal width of the femur, and protruding length of the nail tip. We expect that these numerical values can be used in the production of new devices with shorter proximal nails, which would be more appropriates for Koreans.","PeriodicalId":410202,"journal":{"name":"The Journal of the Korean Hip Society","volume":"22 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Journal of the Korean Hip Society","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5371/JKHS.2011.23.4.303","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

Purpose: We propose to improve the use of Proximal Femoral Nail Anti-rotation in Korea by reporting anatomical measurements of the normal Korean proximal femur. Materials and Methods: A total of 230 patients were enrolled who had all experienced a femoral intertrochanteric fracture and undergone the Proximal Femoral Nail Anti-rotation surgical procedure between February 2007 and April 2011. We measured the neck-shaft angle and endosteal width at the isthmus of a normal femur, and the distance between the greater trochanter and the nail tip of the Proximal Femoral Nail Anti-rotation in post-operative plain radiography. We analyzed the average and standard deviations of the measurements. We also investigated correlations with the patient gender. Results: The average neck-shaft angle and endosteal width at the isthmus were 129.7。(111.0~138.3。 ) and 14.5 mm (9.7~23.1 mm), respectively. The average protruded nail length was 4.9 mm (1.0~15.0 mm). The femur neck-shaft angle had a correlation ratio with gender (p=0.000). However, the endosteal width at the isthmus level and the protruded nail length had no correlation ratio with gender (p=0.108, 0.573, respectively). Conclusion: Until now, in intertrochanteric fracture operations using Proximal Femoral Nail Anti-rotation, the selection of devices has been extremely limited. Through this study we present the average Korean anatomical neckshaft angle, endosteal width of the femur, and protruding length of the nail tip. We expect that these numerical values can be used in the production of new devices with shorter proximal nails, which would be more appropriates for Koreans.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
正常韩国股骨近端x线平片解剖测量:使用股骨近端钉防旋转时的一个问题
目的:我们建议通过报告正常韩国股骨近端解剖测量来改善韩国股骨近端防旋转的使用。材料和方法:在2007年2月至2011年4月期间,共有230例患者经历了股骨粗隆间骨折并接受了股骨近端钉抗旋转手术。我们在术后平片中测量了正常股骨峡部颈轴角和骨内宽度,以及股骨大转子与股骨近端防旋转钉尖之间的距离。我们分析了测量结果的平均值和标准差。我们还调查了与患者性别的相关性。结果:峡部颈轴角和骨内宽度平均为129.7。(111.0~138.3 .)14.5 mm (9.7~23.1 mm)。平均突出钉长度为4.9 mm (1.0~15.0 mm)。股骨颈干角与性别有相关性(p=0.000)。峡部骨内膜宽度和甲突长度与性别无相关性(p分别为0.108、0.573)。结论:到目前为止,股骨近端防旋钉在股骨粗隆间骨折手术中,装置的选择非常有限。通过这项研究,我们介绍了韩国人平均解剖颈轴角、股骨骨内宽度和趾尖突出长度。我们期望这些数值可以用于生产更适合韩国人的近端钉更短的新装置。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
The Aim of Medicine Comparative Analysis of Two Cementless Stems in Total Hip Arthroplasties in Patients with Osteonecrosis of Femoral Head - Summit® Stem and Bencox® Stem - Repeated Ceramic Head Fracture after Ceramic-on-ceramic Total Hip Arthroplasty Cementless Total Hip Arthroplasty in Dysplastic Hips Hip Arthroplasty Using Collarless Polished Tapered Stem -Minimum 2 Years Follow-up Results-
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1