{"title":"Cell for measurement of dielectric permittivity of solutions","authors":"G. Glibitskiy, V. Maleev, E. V. Izhyk","doi":"10.1109/MSMW.2010.5546085","DOIUrl":null,"url":null,"abstract":"The cell for measurement of dielectric permittivity is intended for research of properties of water solutions in the range of temperatures from 0 to 70°C in a range of frequencies of 30–40 GHz. The simplified construction of a cell is presented on Fig.1. The cell consists of the camera for solution and insert. The camera for a solution consists from waveguide flange with a segment of a circular waveguide 1, capacities for a solution 2, insert for the thermometer 3 with an entry branch pipe for flood filling of a solution, an output branch pipe for change of a solution 4. The segment of a circular waveguide has round deepening for glass tight laying from side capacities for a solution. The insert consists from waveguide a flange with a segment of a circular waveguide 5 and tanks 6 with a cylindrical part. The tank has round deepening for glass tight laying from side capacities for a solution also. Glass tight layings are pasted compound glue. The camera and an insert are made of stainless steel and incorporate by screws. Laying from high-temperature moisture resistant rubber is allocated between the camera and an insert for hermetic connection. The camera and insert have plane side surfaces. Heating units are attached to these surfaces by means of slices. The heating unit represents twelve ceramic resistances (on six cells from each side) with admissible power of 10 Watt everyone and with rating value of 72 Ohm. Resistances are connected in a parallel way. For cell heating the heating unit was connected to an alternating voltage source which regulated a range from 5 to 10 Volt so that speed of heating of a solution in a cell was no more than one degree for two minutes.","PeriodicalId":129834,"journal":{"name":"2010 INTERNATIONAL KHARKOV SYMPOSIUM ON PHYSICS AND ENGINEERING OF MICROWAVES, MILLIMETER AND SUBMILLIMETER WAVES","volume":"76 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2010-06-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2010 INTERNATIONAL KHARKOV SYMPOSIUM ON PHYSICS AND ENGINEERING OF MICROWAVES, MILLIMETER AND SUBMILLIMETER WAVES","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/MSMW.2010.5546085","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The cell for measurement of dielectric permittivity is intended for research of properties of water solutions in the range of temperatures from 0 to 70°C in a range of frequencies of 30–40 GHz. The simplified construction of a cell is presented on Fig.1. The cell consists of the camera for solution and insert. The camera for a solution consists from waveguide flange with a segment of a circular waveguide 1, capacities for a solution 2, insert for the thermometer 3 with an entry branch pipe for flood filling of a solution, an output branch pipe for change of a solution 4. The segment of a circular waveguide has round deepening for glass tight laying from side capacities for a solution. The insert consists from waveguide a flange with a segment of a circular waveguide 5 and tanks 6 with a cylindrical part. The tank has round deepening for glass tight laying from side capacities for a solution also. Glass tight layings are pasted compound glue. The camera and an insert are made of stainless steel and incorporate by screws. Laying from high-temperature moisture resistant rubber is allocated between the camera and an insert for hermetic connection. The camera and insert have plane side surfaces. Heating units are attached to these surfaces by means of slices. The heating unit represents twelve ceramic resistances (on six cells from each side) with admissible power of 10 Watt everyone and with rating value of 72 Ohm. Resistances are connected in a parallel way. For cell heating the heating unit was connected to an alternating voltage source which regulated a range from 5 to 10 Volt so that speed of heating of a solution in a cell was no more than one degree for two minutes.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
测量溶液介电常数的电池
用于测量介电常数的电池用于研究在30-40 GHz频率范围内温度范围为0至70°C的水溶液的性质。单元格的简化构造如图1所示。该电池由用于溶液的照相机和插入物组成。所述用于溶液的摄像机包括:带有一段圆波导1的波导法兰、用于溶液的容量2、用于温度计3的插入、用于溶液填充的入口分支管、用于溶液更换的输出分支管4。圆波导的部分具有圆形加深,用于从侧面解决方案的玻璃紧密铺设。所述插入件由波导、带一段圆形波导5的法兰和带圆柱形部分的贮槽6组成。该罐具有圆形加深,用于玻璃紧密铺设,从侧面也可以解决问题。玻璃密层是用复合胶粘贴的。相机和插片由不锈钢制成,用螺丝固定。高温防潮橡胶敷设在相机和密封件之间,用于密封连接。相机和插片有平面侧面。加热装置通过薄片连接在这些表面上。加热单元代表12个陶瓷电阻(每侧6个单元),每个电阻的允许功率为10瓦,额定值为72欧姆。电阻以并联方式连接。对于电池加热,加热单元连接到一个交流电压源,该电压源调节范围为5至10伏,以便电池中溶液的加热速度在两分钟内不超过一度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Numerical model for calculating eigen-mode spectrum of complicated cross-section waveguides Energy of activation of saccharose in solutions Robust DFT-based signal processing in Micro-Doppler radars Coupled disk, half-disk and spiral resonators with whispering gallery-like modes Azimuth angle errors as affected Fresnel diffraction on the large obstacles
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1