Characterization of a PET camera optimized for prostate imaging

J. Huber, W. Choong, W. Moses, J. Qi, J. Hu, G. Wang, D. Wilson, S. Oh, R. Huesman, S. Derenzo
{"title":"Characterization of a PET camera optimized for prostate imaging","authors":"J. Huber, W. Choong, W. Moses, J. Qi, J. Hu, G. Wang, D. Wilson, S. Oh, R. Huesman, S. Derenzo","doi":"10.1109/NSSMIC.2005.1596615","DOIUrl":null,"url":null,"abstract":"We present the characterization of a positron emission tomograph for prostate imaging that centers a patient between a pair of external curved detector banks (ellipse: 45 cm minor, 70 cm major axis). The distance between detector banks adjusts to allow patient access and to position the detectors as closely as possible for maximum sensitivity with patients of various sizes. Each bank is composed of two axial rows of 20 HR+ block detectors for a total of 80 detectors in the camera. The individual detectors are angled in the transaxial plane to point towards the prostate to reduce resolution degradation in that region. The detectors are read out by modified HRRT data acquisition electronics. Compared to a standard whole-body PET camera, our dedicated-prostate camera has the same sensitivity and resolution, less background (less randoms and lower scatter fraction) and a lower cost. We have completed construction of the camera. Characterization data and reconstructed images of several phantoms are shown. Sensitivity of a point source in the center is 946 cps/muCi. Spatial resolution is 4 mm FWHM in the central region","PeriodicalId":105619,"journal":{"name":"IEEE Nuclear Science Symposium Conference Record, 2005","volume":"24 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2005-11-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Nuclear Science Symposium Conference Record, 2005","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NSSMIC.2005.1596615","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

Abstract

We present the characterization of a positron emission tomograph for prostate imaging that centers a patient between a pair of external curved detector banks (ellipse: 45 cm minor, 70 cm major axis). The distance between detector banks adjusts to allow patient access and to position the detectors as closely as possible for maximum sensitivity with patients of various sizes. Each bank is composed of two axial rows of 20 HR+ block detectors for a total of 80 detectors in the camera. The individual detectors are angled in the transaxial plane to point towards the prostate to reduce resolution degradation in that region. The detectors are read out by modified HRRT data acquisition electronics. Compared to a standard whole-body PET camera, our dedicated-prostate camera has the same sensitivity and resolution, less background (less randoms and lower scatter fraction) and a lower cost. We have completed construction of the camera. Characterization data and reconstructed images of several phantoms are shown. Sensitivity of a point source in the center is 946 cps/muCi. Spatial resolution is 4 mm FWHM in the central region
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
一种用于前列腺成像优化的PET相机的特性
我们介绍了一种用于前列腺成像的正电子发射断层成像的特征,该成像将患者集中在一对外部弯曲检测器组之间(椭圆:45厘米长轴,70厘米长轴)。探测器组之间的距离调整,以允许患者进入,并将探测器放置在尽可能近的位置,以获得对各种大小的患者的最大灵敏度。每组由两排轴向的20个HR+块探测器组成,相机中总共有80个探测器。单个探测器在跨轴平面上成角度指向前列腺,以减少该区域的分辨率下降。探测器通过改进的HRRT数据采集电子设备读出。与标准的全身PET相机相比,我们的专用前列腺相机具有相同的灵敏度和分辨率,更少的背景(更少的随机和更低的散射分数)和更低的成本。我们已经完成了照相机的构造。给出了几个幻影的表征数据和重建图像。中心点源的灵敏度为946 cps/muCi。中心区域空间分辨率为4mm FWHM
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Monte Carlo optimization of an industrial tomography system A scalable system for microcalcification cluster automated detection in a distributed mammographic database The BaBar muon system upgrade Fast, long-wavelength scintillators and waveshifters New effects observed in the BaBar silicon vertex tracker: interpretation and estimate of their impact on the future performance of the detector
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1