Spectroscopic Study of Radiation from Double Planar Mo Wire Arrays (uniform and combined with Al) produced on the 1 MA Zebra Generator at UNR

F. Yilmaz, A. Safronova, V. Kantsyrev, K. Williamson, G. Osborne, I. Shrestha, N. Ouart
{"title":"Spectroscopic Study of Radiation from Double Planar Mo Wire Arrays (uniform and combined with Al) produced on the 1 MA Zebra Generator at UNR","authors":"F. Yilmaz, A. Safronova, V. Kantsyrev, K. Williamson, G. Osborne, I. Shrestha, N. Ouart","doi":"10.1109/PPPS.2007.4345715","DOIUrl":null,"url":null,"abstract":"Summary form only given. Recently, double planar wire array (DPWA) experiments with Al wires have been performed on the 1 MA Zebra generator at UNR and their radiative properties were studied in Kantsyrev et al. [2006]. In the present work the spectroscopic analysis of the implosions of DPWA with Mo wires on the 1 MA Zebra at UNR is presented. These DPWAs consisted of 8-10 wires with the interwire separation of 0.7-1 mm in each of two parallel rows. The distance between rows was 3 mm. Uniform DPWA from Mo wires as well as combined with Al wires were considered. Mo wires were about 8 mum in diameter and Al wires were 10-18 mum alloyed Al 5056 (95% of Al and 5% Mg) wires. The use of this type of alloyed Al wires was important for plasma diagnostics. Total energy yields for the Mo DPWA (maximum of 24 kJ) were not only higher than for the Al DPWA (maximum of 11 kJ) but exceeded that for the Mo single planar arrays (maximum of 19 kJ). Data from fast X- ray detectors, both time-gated and time integrated X-ray pinhole cameras, and spatially-resolved (time integrated) and time-gated (spatially integrated) spectrometers were analyzed. Non-LTE CR models of Mo as well as of Mg and Al were applied to analyze L-shell Mo and K-shell Mg and Al X-ray spectra. Opacity of the Mo and Al lines was also studied. The results of modeling of radiation from DPWA were compared with the similar results from the Mo single planar wire arrays. In addition modeling of time-gated spectra is presented which provides important information on the temporal plasma evolution produced by DPWA.","PeriodicalId":446230,"journal":{"name":"2007 IEEE 34th International Conference on Plasma Science (ICOPS)","volume":"13 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2007-06-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2007 IEEE 34th International Conference on Plasma Science (ICOPS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PPPS.2007.4345715","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Summary form only given. Recently, double planar wire array (DPWA) experiments with Al wires have been performed on the 1 MA Zebra generator at UNR and their radiative properties were studied in Kantsyrev et al. [2006]. In the present work the spectroscopic analysis of the implosions of DPWA with Mo wires on the 1 MA Zebra at UNR is presented. These DPWAs consisted of 8-10 wires with the interwire separation of 0.7-1 mm in each of two parallel rows. The distance between rows was 3 mm. Uniform DPWA from Mo wires as well as combined with Al wires were considered. Mo wires were about 8 mum in diameter and Al wires were 10-18 mum alloyed Al 5056 (95% of Al and 5% Mg) wires. The use of this type of alloyed Al wires was important for plasma diagnostics. Total energy yields for the Mo DPWA (maximum of 24 kJ) were not only higher than for the Al DPWA (maximum of 11 kJ) but exceeded that for the Mo single planar arrays (maximum of 19 kJ). Data from fast X- ray detectors, both time-gated and time integrated X-ray pinhole cameras, and spatially-resolved (time integrated) and time-gated (spatially integrated) spectrometers were analyzed. Non-LTE CR models of Mo as well as of Mg and Al were applied to analyze L-shell Mo and K-shell Mg and Al X-ray spectra. Opacity of the Mo and Al lines was also studied. The results of modeling of radiation from DPWA were compared with the similar results from the Mo single planar wire arrays. In addition modeling of time-gated spectra is presented which provides important information on the temporal plasma evolution produced by DPWA.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
在UNR的1ma Zebra发生器上产生的双平面Mo线阵列(均匀和结合Al)辐射的光谱研究
只提供摘要形式。最近,在UNR的1ma Zebra发电机上进行了Al导线双平面导线阵列(DPWA)实验,Kantsyrev等[2006]研究了其辐射特性。本文介绍了在UNR的1ma斑马上用钼线对DPWA内爆的光谱分析。这些dpwa由8-10根导线组成,每两行导线之间的间距为0.7-1毫米。行与行之间的距离为3mm。考虑了由Mo线和Al线组成的均匀DPWA。Mo丝直径约为8 μ m, Al丝为10 ~ 18 μ m的al5056合金丝(95% Al和5% Mg)。这种合金铝丝的使用对等离子诊断非常重要。Mo DPWA的总能量产率(最大24 kJ)不仅高于Al DPWA的总能量产率(最大11 kJ),而且超过了Mo单平面阵列的总能量产率(最大19 kJ)。分析了来自快速X射线探测器、时间门控和时间积分X射线针孔相机、空间分辨(时间积分)和时间门控(空间积分)光谱仪的数据。采用Mo、Mg和Al的非lte CR模型分析了l壳层Mo和k壳层Mg和Al的x射线光谱。还研究了Mo和Al线的不透明度。将模拟结果与Mo单面线阵列的模拟结果进行了比较。此外,还建立了时间门控谱模型,为研究等离子体的时间演化提供了重要的信息。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
相关文献
Forecasting TAIFEX based on fuzzy time series and particle swarm optimization
IF 8.5 1区 计算机科学Expert Systems with ApplicationsPub Date : 2010-03-01 DOI: 10.1016/j.eswa.2009.06.102
I-Hong Kuo , Shi-Jinn Horng , Yuan-Hsin Chen , Ray-Shine Run , Tzong-Wann Kao , Rong-Jian Chen , Jui-Lin Lai , Tsung-Lieh Lin
Forecasting TAIFEX based on fuzzy time series and particle swarm optimization
IF 0 Expert Syst. Appl.Pub Date : 2010-03-01 DOI: 10.1016/j.eswa.2009.06.102
I-Hong Kuo, S. Horng, Yuan-Hsin Chen, R. Run, T. Kao, Rong-Jian Chen, Jui-Lin Lai, Tsung-Lieh Lin
Chaotic Time Series Prediction Based On Binary Particle Swarm Optimization
IF 0 AASRI ProcediaPub Date : 2012-01-01 DOI: 10.1016/j.aasri.2012.06.058
Xiaoxiao Cui, Mingyan Jiang
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Production of nitrogen-containing carbon plasma using shunting arc discharge for carbon nitride films preparation Opening Switch Utilizing Shock Wave Induced Conduction in PMMA and PVC The Dynamics of Radiation Driven Gap Closure Across Megagauss Fields on Z Potential Applications of Tandem Shock Waves in Cancer Treatment Single Wire Electrode Contacts ABD their Effects on Energy Deposition
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1