{"title":"A comparative study in improvement of voltage security in a multi-bus power system using STATCOM and SVC","authors":"P. Das, S. H. nee Dey, A. Chakrabarti, T. Datta","doi":"10.1109/ICEAS.2011.6147129","DOIUrl":null,"url":null,"abstract":"In this paper an effort is made to assess local and global voltage security of multi-bus power system in presence of STATCOM and SVC. A Global Voltage Security Indicator (GVSI) derived from series network equivalent of multi-bus power system has been employed to assess overall system voltage security. Thevenin's equivalent of the power system with respect to a particular load bus has been used to assess the local voltage security. A comparative study on effectiveness of STATCOM and SVC in improvement of voltage security using network equivalents has also been presented and validated using the well known L-index. STATCOM found to be more effective than SVC to ensure voltage security and at the same time it is also capable to reduce reactive power line loss considerably.","PeriodicalId":273164,"journal":{"name":"2011 International Conference on Energy, Automation and Signal","volume":"22 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 International Conference on Energy, Automation and Signal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICEAS.2011.6147129","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 8
Abstract
In this paper an effort is made to assess local and global voltage security of multi-bus power system in presence of STATCOM and SVC. A Global Voltage Security Indicator (GVSI) derived from series network equivalent of multi-bus power system has been employed to assess overall system voltage security. Thevenin's equivalent of the power system with respect to a particular load bus has been used to assess the local voltage security. A comparative study on effectiveness of STATCOM and SVC in improvement of voltage security using network equivalents has also been presented and validated using the well known L-index. STATCOM found to be more effective than SVC to ensure voltage security and at the same time it is also capable to reduce reactive power line loss considerably.