{"title":"Performance of the VITEK2 System for Detection of Inducible Clindamycin Resistance in Staphylococci","authors":"M. K. Kim, J. Hong, Miae Lee","doi":"10.5145/KJCM.2010.13.4.157","DOIUrl":null,"url":null,"abstract":"Background: The Clinical and Laboratory Standards Institute (CLSI) recommends testing for inducible clindamycin resistance in clindamycin non-resistant and erythromycin resistant (CNR-ER) staphylococci by using a D-zone test. Recently, the VITEK2 system was developed to detect inducible clindamycin resistance in staphylococci. We evaluated the performance of the VITEK2 system by comparing it with a D-zone test. Methods: In detecting inducible clindamycin resistance, a total of 142 clinical isolates of staphylococci were tested by using the VITEK2 Antimicrobial Susceptibility Test (AST)-P601 card (bioMerieux, Marcy l’Etoile, France) and the D-zone test. Of the 142 isolates of staphylococci tested, 114 were CNR-ER staphylococci [40 coagulase-negative staphylococci (CoNS), 74 Staphylococcus aureus] and 28 were staphylococci, either resistant or susceptible to clindamycin and erythromycin (1 CoNS and 27 S. aureus). Results: Of the 114 CNR-ER staphylococci, 98.6% (73/74) of S. aureus and 32.5% (13/40) of CoNS were inducible clindamycin resistant according to the Dzone test. Overall sensitivity and specificity of the VITEK2 system were 98.8% (85/86) and 98.2% (55/56) respectively, and the agreement between the VITEK2 system and the D-zone test was 98.6% (140/142). Conclusion: The VITEK2 system shows high concordance with a D-zone test. The inducible clindamycin resistance in staphylococci can be detected easily and conveniently by the VITEK2 system. (Korean J Clin Microbiol 2010;13:157-161)","PeriodicalId":143093,"journal":{"name":"Korean Journal of Clinical Microbiology","volume":"89 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2010-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Korean Journal of Clinical Microbiology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5145/KJCM.2010.13.4.157","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Background: The Clinical and Laboratory Standards Institute (CLSI) recommends testing for inducible clindamycin resistance in clindamycin non-resistant and erythromycin resistant (CNR-ER) staphylococci by using a D-zone test. Recently, the VITEK2 system was developed to detect inducible clindamycin resistance in staphylococci. We evaluated the performance of the VITEK2 system by comparing it with a D-zone test. Methods: In detecting inducible clindamycin resistance, a total of 142 clinical isolates of staphylococci were tested by using the VITEK2 Antimicrobial Susceptibility Test (AST)-P601 card (bioMerieux, Marcy l’Etoile, France) and the D-zone test. Of the 142 isolates of staphylococci tested, 114 were CNR-ER staphylococci [40 coagulase-negative staphylococci (CoNS), 74 Staphylococcus aureus] and 28 were staphylococci, either resistant or susceptible to clindamycin and erythromycin (1 CoNS and 27 S. aureus). Results: Of the 114 CNR-ER staphylococci, 98.6% (73/74) of S. aureus and 32.5% (13/40) of CoNS were inducible clindamycin resistant according to the Dzone test. Overall sensitivity and specificity of the VITEK2 system were 98.8% (85/86) and 98.2% (55/56) respectively, and the agreement between the VITEK2 system and the D-zone test was 98.6% (140/142). Conclusion: The VITEK2 system shows high concordance with a D-zone test. The inducible clindamycin resistance in staphylococci can be detected easily and conveniently by the VITEK2 system. (Korean J Clin Microbiol 2010;13:157-161)