Dynamic compression plating with interlocking nailing for fracture shaft of humerus in adult: A prospective study

Arvind Kumar
{"title":"Dynamic compression plating with interlocking nailing for fracture shaft of humerus in adult: A prospective study","authors":"Arvind Kumar","doi":"10.26611/10202132","DOIUrl":null,"url":null,"abstract":"Background: In orthopaedics, a humerus fracture is a frequent yet difficult to treat problem. Unless complicated, these are normally treated non-operatively (with a hanging arm cast, U cast, or U slab). Complete union is not always required since the bone has a dense covering of muscles and blood vessels. The goal of this study was to see if there was a difference between dynamic compression plating (DCP) and intramedullary interlocking nailing in diaphyseal humeral fractures in adults. Methods: It was a prospective study undertaken at MGM Medical College and L.S.K. Hospital in Kishanganj, Bihar, in the department of orthopaedics. During the study period of November 2020 to September 2021, a total of 40 cases were enrolled. The participants in the study were randomly assigned to one of two groups. One closed reduction and internal fixation with antegrade intramedullary interlocking nail-group, and one open reduction and internal fixation with dynamic compression plating-group. Results: We found that the final outcome in between the groups, comparison of DASH score, maximum number of excellent cases were Dynamic compression plating group. i.e. 80.0%, good-13.3%, Fair was 6.7% respectively. In another Interlocking nailing group excellent cases were found 26.7%, good-33.3%, fair- 26.7% and poor was 13.3% respectively. We have found statistically significant p value -0.028. Conclusion: There appears to be a substantial difference in radiological union or rate of union between the two groups; nonetheless, based on complications and functional results, Dynamic compression plating is a good fixation method","PeriodicalId":126695,"journal":{"name":"MedPulse International Journal of Orthopedics","volume":"3 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"MedPulse International Journal of Orthopedics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.26611/10202132","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background: In orthopaedics, a humerus fracture is a frequent yet difficult to treat problem. Unless complicated, these are normally treated non-operatively (with a hanging arm cast, U cast, or U slab). Complete union is not always required since the bone has a dense covering of muscles and blood vessels. The goal of this study was to see if there was a difference between dynamic compression plating (DCP) and intramedullary interlocking nailing in diaphyseal humeral fractures in adults. Methods: It was a prospective study undertaken at MGM Medical College and L.S.K. Hospital in Kishanganj, Bihar, in the department of orthopaedics. During the study period of November 2020 to September 2021, a total of 40 cases were enrolled. The participants in the study were randomly assigned to one of two groups. One closed reduction and internal fixation with antegrade intramedullary interlocking nail-group, and one open reduction and internal fixation with dynamic compression plating-group. Results: We found that the final outcome in between the groups, comparison of DASH score, maximum number of excellent cases were Dynamic compression plating group. i.e. 80.0%, good-13.3%, Fair was 6.7% respectively. In another Interlocking nailing group excellent cases were found 26.7%, good-33.3%, fair- 26.7% and poor was 13.3% respectively. We have found statistically significant p value -0.028. Conclusion: There appears to be a substantial difference in radiological union or rate of union between the two groups; nonetheless, based on complications and functional results, Dynamic compression plating is a good fixation method
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
动态加压钢板联锁钉治疗成人肱骨骨折:一项前瞻性研究
背景:在骨科中,肱骨骨折是一个常见而又难以治疗的问题。除非病情复杂,否则通常采用非手术治疗(吊臂石膏、U型石膏或U型板)。由于骨骼有一层致密的肌肉和血管覆盖,因此并不总是需要完全愈合。本研究的目的是观察在成人肱骨骨干骨折中,动态加压钢板(DCP)和髓内交锁钉治疗是否存在差异。方法:在比哈尔邦基尚甘杰市米高梅医学院和L.S.K.医院骨科进行前瞻性研究。研究期间为2020年11月至2021年9月,共入组病例40例。研究参与者被随机分为两组。顺行交锁髓内钉组闭合复位内固定1例,动力加压钢板组开放复位内固定1例。结果:我们发现在两组间的最终疗效、DASH评分比较中,优病例数最多的是动态加压钢板组。即80.0%,good-13.3%, Fair分别为6.7%。交锁钉组优者26.7%,良者33.3%,一般者26.7%,差者13.3%。我们发现p值有统计学意义-0.028。结论:两组在放射愈合或愈合率上存在显著差异;然而,基于并发症和功能结果,动态加压钢板是一种很好的固定方法
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Comparison of case-based learning with didactic learning in the clinical teaching of orthopaedics Cross sectional study to determine the prevalence of osteoporosis and osteopenia in rural people of Thiruvarur district, Tamil Nadu, India Study of epidemiology, clinical features and early outcome in traumatic spine injuries at a tertiary hospital in Jammu region Lumbar spondylosis and epidural steroid injection: Our experience at a tertiary care centre A study of role of obesity in the chondral lesions of isolated medial meniscus tears at tertiary health care centre
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1