Ultrasonic system for fuel assembly inspection in pressurized water reactors

Z. Thome, W. Pereira, J. C. Machado, J. Seixas, W. S. Filho, J.L. Chapot
{"title":"Ultrasonic system for fuel assembly inspection in pressurized water reactors","authors":"Z. Thome, W. Pereira, J. C. Machado, J. Seixas, W. S. Filho, J.L. Chapot","doi":"10.1109/ULTSYM.2000.922661","DOIUrl":null,"url":null,"abstract":"Ultrasonic pulses (center frequency at 25 MHz) are incident on the rods of fuel assemblies. The echoes from the tube front wall as well as from the multireflections at the interface between the tube inner wall/gap were collected from a fuel assembly prototype containing intact rods and failed ones (water in the gap between the tube inner wall and the fuel). Detection of failed rods is based on signal analysis of the echo envelopes, employing three methods: exponential envelope estimation, Fisher linear discriminant and neural networks. Around 5,000 US signals were processed and up to 93% of failed rods were correctly identified, for a false alarm detection smaller than 2%.","PeriodicalId":350384,"journal":{"name":"2000 IEEE Ultrasonics Symposium. Proceedings. An International Symposium (Cat. No.00CH37121)","volume":"28 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2000-10-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2000 IEEE Ultrasonics Symposium. Proceedings. An International Symposium (Cat. No.00CH37121)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ULTSYM.2000.922661","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

Ultrasonic pulses (center frequency at 25 MHz) are incident on the rods of fuel assemblies. The echoes from the tube front wall as well as from the multireflections at the interface between the tube inner wall/gap were collected from a fuel assembly prototype containing intact rods and failed ones (water in the gap between the tube inner wall and the fuel). Detection of failed rods is based on signal analysis of the echo envelopes, employing three methods: exponential envelope estimation, Fisher linear discriminant and neural networks. Around 5,000 US signals were processed and up to 93% of failed rods were correctly identified, for a false alarm detection smaller than 2%.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
压水堆燃料组件超声检测系统
超声脉冲(中心频率为25兆赫)入射到燃料组件的棒上。从包含完整棒和失效棒(管内壁和燃料间隙中的水)的燃料组件原型中收集了来自管前壁以及管内壁/间隙之间界面的多反射回波。失效杆的检测基于对回波包络信号的分析,采用指数包络估计、Fisher线性判别和神经网络三种方法。大约5000个美国信号被处理,高达93%的故障棒被正确识别,误报检出率低于2%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Differentiation of moving scatterers with different velocities using trapezoid filter and pulse echo ultrasound Lesion resolution following exposure of rat lung to pulsed ultrasound Role of pulse repetition frequency and exposure duration on the superthreshold behavior of ultrasound-induced lung haemorrhage in adult mice and rats Thick film sol gel PZT transducer using dip coating Towards ultrasonic brain imaging
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1