Renal Distraction during Percutaneous Renal Calyceal Access for Prone & Supine PCNL Using a Ureteric Balloon Catheter (UBC).

H. Rooney, M. Alsawi, T. Amer, L. Mokool, W. Maynard, R. Khan, S. Nalagatla
{"title":"Renal Distraction during Percutaneous Renal Calyceal Access for Prone & Supine PCNL Using a Ureteric Balloon Catheter (UBC).","authors":"H. Rooney, M. Alsawi, T. Amer, L. Mokool, W. Maynard, R. Khan, S. Nalagatla","doi":"10.22374/JELEU.V2I3.42","DOIUrl":null,"url":null,"abstract":"Special access techniques during percutaneous nephrolithotomy (PCNL) are indicated for challenging stones. Various techniques have been described to inferiorly displace the kidney to facilitate optimal percutaneous access whilst minimizing thoracic complications associated with the supracostal approach. \nWe describe our institution’s technique of using a ureteric balloon catheter to inferiorly distract and immobilize the kidney (UBC Technique) to achieve the optimal calyceal access infracostally during PCNL. This permits effective and safe access in a single puncture whilst additionally stabilizing the renal unit during respiration and reducing the skin-to-calyceal distance by mobilizing the desired calyx in line with the axis of the puncture needle.  We reviewed the literature regarding alternative inferior renal displacement techniques permitting infracostal approaches.  \nFrom May 2012 to October 2017 150 PCNLs were performed in our institution. Out of these, the UBC technique was used in 18 cases during both prone and supine PCNLs. In all cases, the UBC technique was used successfully to access the most desirable calyx. No complications associated with renal distraction were reported. Post operatively, 1 patient required a blood transfusion, 1 patient had a pyrexia of >38 degrees resulting in a longer admission and 1 patient developed sepsis requiring HDU admission for monitoring only. 15 out the 18 patients had complete stone clearance from their PCNL. \nThe UBC technique provides a safe alternative to the supracostal approach in percutaneous renal surgery. It is less traumatic than alternative infracostal access techniques and has a very short learning curve. \n  \n ","PeriodicalId":136362,"journal":{"name":"Journal of Endoluminal Endourology","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-09-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Endoluminal Endourology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.22374/JELEU.V2I3.42","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Special access techniques during percutaneous nephrolithotomy (PCNL) are indicated for challenging stones. Various techniques have been described to inferiorly displace the kidney to facilitate optimal percutaneous access whilst minimizing thoracic complications associated with the supracostal approach. We describe our institution’s technique of using a ureteric balloon catheter to inferiorly distract and immobilize the kidney (UBC Technique) to achieve the optimal calyceal access infracostally during PCNL. This permits effective and safe access in a single puncture whilst additionally stabilizing the renal unit during respiration and reducing the skin-to-calyceal distance by mobilizing the desired calyx in line with the axis of the puncture needle.  We reviewed the literature regarding alternative inferior renal displacement techniques permitting infracostal approaches.  From May 2012 to October 2017 150 PCNLs were performed in our institution. Out of these, the UBC technique was used in 18 cases during both prone and supine PCNLs. In all cases, the UBC technique was used successfully to access the most desirable calyx. No complications associated with renal distraction were reported. Post operatively, 1 patient required a blood transfusion, 1 patient had a pyrexia of >38 degrees resulting in a longer admission and 1 patient developed sepsis requiring HDU admission for monitoring only. 15 out the 18 patients had complete stone clearance from their PCNL. The UBC technique provides a safe alternative to the supracostal approach in percutaneous renal surgery. It is less traumatic than alternative infracostal access techniques and has a very short learning curve.    
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
输尿管球囊导管(UBC)用于俯卧位PCNL的经皮肾盏通路中的肾脏牵张。
在经皮肾镜取石术(PCNL)中需要特殊的通路技术。各种技术已被描述为下移位肾脏,以促进最佳的经皮入路,同时最大限度地减少与肋上入路相关的胸部并发症。我们描述了我们机构在PCNL期间使用输尿管球囊导管向下分散和固定肾脏的技术(UBC技术),以实现最佳的肾盏下通道。这允许在单次穿刺中有效和安全的进入,同时在呼吸过程中稳定肾脏单位,并通过动员所需的花萼与穿刺针的轴线保持一致来减少皮肤到肾盏的距离。我们回顾了关于允许肋下入路的替代下肾移位技术的文献。2012年5月至2017年10月,我院共实施pcnl 150例。其中,18例俯卧位和仰卧位pcnl均采用了UBC技术。在所有情况下,UBC技术都成功地获得了最理想的花萼。无与肾分散相关的并发症报道。术后1例患者需要输血,1例患者发热>38度导致住院时间延长,1例患者出现败血症需要HDU住院监测。18例患者中有15例完全清除了PCNL的结石。在经皮肾外科手术中,UBC技术为肋上入路提供了一个安全的选择。它比其他的肋下入路技术创伤更小,学习曲线也很短。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Inverted Y Ureteral Duplication with Distal Obstructing Calculi in the Ectopic Ureter in the Prostatic Urethra Post-operative Events with Post-operative Day One Stent Removal after Percutaneous Nephrolithotomy Teflon Injections (STING) Mimicking Distal Ureteric Stones Proceedings of the Welsh Urological Society Annual Meeting The Role of the ClearPetra Suction Access Sheath and UROFINO Disposable Ureteroscope as an Alternative to PCNL/Conventional Flexible Ureteroscopy for a Large Renal Pelvis Stone
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1