Waveform Correlation Based Harmonic Voltage Contribution Determination of Iron and Steel Plants Supplied From PCC

Mustafa Çalişkan, Özgül Salor-Durna, M. Çiydem
{"title":"Waveform Correlation Based Harmonic Voltage Contribution Determination of Iron and Steel Plants Supplied From PCC","authors":"Mustafa Çalişkan, Özgül Salor-Durna, M. Çiydem","doi":"10.1109/IAS54023.2022.9939680","DOIUrl":null,"url":null,"abstract":"In this research work, a new method which determines the individual harmonic voltage contributions of the EAF plants supplied from a point of common coupling (PCC) to the PCC voltage is presented. EAFs are one of the most significant sources of the harmonics, especially the uncharacteristic ones, therefore it is important to be able to discriminate the amount of individual contributions from the feeders of a PCC supplying multiple EAFs. The proposed method uses the relationship derived between the correlation coefficient of the PCC voltage and the feeder current waveforms and the harmonic voltage contribution of each plant supplied from the PCC. The main idea is based on the fact that harmonic voltage at the PCC is a result of the additive effect of voltage drops on the source side impedance of the power system caused by the individual feeder currents. After computing the Pearson correlation coefficients at each harmonic frequency using 10-cycle synchronized feeder current and PCC voltage waveforms, harmonic voltage contribution of the related feeder is obtained using the proposed method. This procedure can be repeatedly used to obtain the contribution of each EAF plant at each frequency component. Field measurements from a PCC supplying multiple EAF plants are used to verify the results and the performance is compared with the previously proposed methods. With a specified source side impedance by the utility, the proposed approach is a fast method of obtaining the harmonic responsibilities, since no real-time impedance measurements are required and no need for the measurements of the other feeders to compute the contribution of a specific feeder in contrast to some other methods. The proposed method can be easily adapted as a real time harmonic contribution detection tool for the power quality analyzers, all of which have synchronized voltage and current waveform measurements.","PeriodicalId":193587,"journal":{"name":"2022 IEEE Industry Applications Society Annual Meeting (IAS)","volume":"646 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-10-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 IEEE Industry Applications Society Annual Meeting (IAS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IAS54023.2022.9939680","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

In this research work, a new method which determines the individual harmonic voltage contributions of the EAF plants supplied from a point of common coupling (PCC) to the PCC voltage is presented. EAFs are one of the most significant sources of the harmonics, especially the uncharacteristic ones, therefore it is important to be able to discriminate the amount of individual contributions from the feeders of a PCC supplying multiple EAFs. The proposed method uses the relationship derived between the correlation coefficient of the PCC voltage and the feeder current waveforms and the harmonic voltage contribution of each plant supplied from the PCC. The main idea is based on the fact that harmonic voltage at the PCC is a result of the additive effect of voltage drops on the source side impedance of the power system caused by the individual feeder currents. After computing the Pearson correlation coefficients at each harmonic frequency using 10-cycle synchronized feeder current and PCC voltage waveforms, harmonic voltage contribution of the related feeder is obtained using the proposed method. This procedure can be repeatedly used to obtain the contribution of each EAF plant at each frequency component. Field measurements from a PCC supplying multiple EAF plants are used to verify the results and the performance is compared with the previously proposed methods. With a specified source side impedance by the utility, the proposed approach is a fast method of obtaining the harmonic responsibilities, since no real-time impedance measurements are required and no need for the measurements of the other feeders to compute the contribution of a specific feeder in contrast to some other methods. The proposed method can be easily adapted as a real time harmonic contribution detection tool for the power quality analyzers, all of which have synchronized voltage and current waveform measurements.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于波形相关的PCC供电钢铁厂谐波电压贡献测定
在本研究中,提出了一种确定从一个共耦合点(PCC)供电的电炉电站各谐波电压对PCC电压贡献的新方法。电场是最重要的谐波来源之一,特别是非特征的谐波,因此能够从PCC提供多个电场的馈线中区分单个贡献的量是很重要的。该方法利用了PCC电压与馈线电流波形的相关系数与PCC供电的各设备的谐波电压贡献之间的关系。其主要思想是基于这样一个事实,即PCC的谐波电压是由单个馈线电流引起的电力系统源侧阻抗上电压降的加性效应的结果。利用10周同步馈线电流和PCC电压波形计算各谐波频率处的Pearson相关系数,得到相应馈线的谐波电压贡献。这个程序可以重复使用,以获得每个EAF厂在每个频率分量的贡献。从一个PCC提供多个电炉厂的现场测量来验证结果,并与先前提出的方法进行了性能比较。与其他方法相比,该方法不需要实时阻抗测量,也不需要测量其他馈线来计算特定馈线的贡献,因此在公用事业指定源侧阻抗的情况下,该方法是一种快速获得谐波责任的方法。该方法可以作为电能质量分析仪的实时谐波贡献检测工具,所有电能质量分析仪都具有同步的电压和电流波形测量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Testing the resistance of conductive gloves for the evaluation of the efficiency of clothing protecting against induced currents Hybrid Machine Learning-based Intelligent Distance Protection and Control Schemes with Fault and Zonal Classification Capabilities for Grid-connected Wind Farms Hardware in the Loop Testing of Main and Backup Protection Scheme for Systems with High Penetration of Inverter-Based Resources Predictive Control of Seven Level Multi-level Inverter Based Single Phase Shunt Active Filter Influence of Ageing on Properties of Insulating Oil in In-Service Transformer and Reactors
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1