Double probe based in piezoelectric sensors for local pulse wave velocity assessment

T. M. Lopes, C. Correia
{"title":"Double probe based in piezoelectric sensors for local pulse wave velocity assessment","authors":"T. M. Lopes, C. Correia","doi":"10.1109/ENBENG.2012.6331386","DOIUrl":null,"url":null,"abstract":"Local pulse-wave velocity (PWV) is recognized as the simplest and most reproducible process of non-invasively assessing the vascular marker of arterial stiffness that allowing the risk of cardiovascular diseases to be determinate. Devices currently available for local PWV measurement have not yet been generalized to clinical practice since they require high technical expertise and most of them are limited in precision, due to the lack of reliable signal processing methods. This work describes a new type of probes, based on a piezoelectric sensor in different configurations, single probe and double probe. The principle of PWV measurement involves determination of the pulse transit time between the signals acquired simultaneously by both piezoelectric placed 23 mm apart in the same probe. The double probe characterization is accomplished in different studies, carried out in a dedicated test bench system, capable of reproducing a range of clinically relevant properties of the cardiovascular system.","PeriodicalId":399131,"journal":{"name":"2012 IEEE 2nd Portuguese Meeting in Bioengineering (ENBENG)","volume":"37 3 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-10-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 IEEE 2nd Portuguese Meeting in Bioengineering (ENBENG)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ENBENG.2012.6331386","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Local pulse-wave velocity (PWV) is recognized as the simplest and most reproducible process of non-invasively assessing the vascular marker of arterial stiffness that allowing the risk of cardiovascular diseases to be determinate. Devices currently available for local PWV measurement have not yet been generalized to clinical practice since they require high technical expertise and most of them are limited in precision, due to the lack of reliable signal processing methods. This work describes a new type of probes, based on a piezoelectric sensor in different configurations, single probe and double probe. The principle of PWV measurement involves determination of the pulse transit time between the signals acquired simultaneously by both piezoelectric placed 23 mm apart in the same probe. The double probe characterization is accomplished in different studies, carried out in a dedicated test bench system, capable of reproducing a range of clinically relevant properties of the cardiovascular system.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于压电传感器的双探头局部脉冲波速评估
局部脉搏波速度(PWV)被认为是最简单和最可重复的无创评估动脉僵硬血管标志物的过程,可以确定心血管疾病的风险。目前可用于局部PWV测量的设备尚未推广到临床实践,因为它们需要很高的技术专长,而且由于缺乏可靠的信号处理方法,大多数设备的精度有限。本工作描述了一种新型的探针,基于压电传感器在不同的配置,单探头和双探头。PWV测量的原理包括确定两个压电在同一探头中相距23mm同时获得的信号之间的脉冲传递时间。双探针表征是在不同的研究中完成的,在一个专门的试验台系统中进行,能够重现心血管系统的一系列临床相关特性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Real-time dynamic monochromatic ocular wavefront aberrations during accommodation: Preliminary results Early detection and monitoring of plant diseases by Bioelectric Impedance Spectroscopy A biomechanical multibody foot model for forward dynamic analysis The impact of rhythms analysis technique on electrographic seizure detection (EEG) Use of Shannon information to relate function and structure in the brain using diffusion spectrum imaging MRI
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1