{"title":"Results of the multicenter evaluation of the CEDIA cortisol assay.","authors":"K Horn,&nbsp;P Haux,&nbsp;R Kattermann,&nbsp;M Oellerich,&nbsp;A Knoke,&nbsp;R Sommer,&nbsp;A Weissmann,&nbsp;M Vockenhuber,&nbsp;D Clark,&nbsp;R H Ng","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>The present paper describes the multicenter evaluation of the CEDIA Cortisol test for total cortisol. The observed linearity of the test was between 1.2 and 50 micrograms/dL cortisol. The limit of detection was calculated as 1.2/dL. Imprecision studies covering the diagnostically relevant range (5-20 micrograms/dL cortisol) yielded coefficients of variation between 1.7-8.9% (within-run) and 2.7-10.5% (between-day). An interlaboratory survey using 41 human samples and three control sera demonstrated that the new CEDIA Cortisol assay has a good interlaboratory transferability. Method comparison studies between the CEDIA Cortisol test and EIA, FIA, FPIA, and various RIAs yielded an acceptable level of agreement and concordant results in most cases. Low cross-reactivity of the antibody used in the new cortisol assay was observed with precursors or metabolites of cortisol. Especially, dexamethasone did not cross-react. However, prednisolone, 6-methylprednisone, and corticosterone showed cross-reactivities. No limitation by endogenous interferences was observed. The CEDIA Cortisol assay permits the precise, fast and sufficiently specific determination of cortisol. Furthermore, it offers the advantages of a non-radioactive assay and can be performed conveniently on Boehringer Mannheim/Hitachi analyzers in combination with routine clinical chemistry.</p>","PeriodicalId":76822,"journal":{"name":"Wiener klinische Wochenschrift. Supplementum","volume":"191 ","pages":"80-5"},"PeriodicalIF":0.0000,"publicationDate":"1992-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Wiener klinische Wochenschrift. Supplementum","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The present paper describes the multicenter evaluation of the CEDIA Cortisol test for total cortisol. The observed linearity of the test was between 1.2 and 50 micrograms/dL cortisol. The limit of detection was calculated as 1.2/dL. Imprecision studies covering the diagnostically relevant range (5-20 micrograms/dL cortisol) yielded coefficients of variation between 1.7-8.9% (within-run) and 2.7-10.5% (between-day). An interlaboratory survey using 41 human samples and three control sera demonstrated that the new CEDIA Cortisol assay has a good interlaboratory transferability. Method comparison studies between the CEDIA Cortisol test and EIA, FIA, FPIA, and various RIAs yielded an acceptable level of agreement and concordant results in most cases. Low cross-reactivity of the antibody used in the new cortisol assay was observed with precursors or metabolites of cortisol. Especially, dexamethasone did not cross-react. However, prednisolone, 6-methylprednisone, and corticosterone showed cross-reactivities. No limitation by endogenous interferences was observed. The CEDIA Cortisol assay permits the precise, fast and sufficiently specific determination of cortisol. Furthermore, it offers the advantages of a non-radioactive assay and can be performed conveniently on Boehringer Mannheim/Hitachi analyzers in combination with routine clinical chemistry.

分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
CEDIA皮质醇测定的多中心评价结果。
本文描述了CEDIA皮质醇测试对总皮质醇的多中心评价。观察到的测试线性在1.2和50微克/分升皮质醇之间。检出限计算为1.2/dL。涵盖诊断相关范围(5-20微克/分升皮质醇)的不精确研究产生的变异系数在1.7-8.9%(运行内)和2.7-10.5%(日间)之间。使用41个人类样本和3个对照血清的实验室间调查表明,新的CEDIA皮质醇测定具有良好的实验室间可转移性。在大多数情况下,CEDIA皮质醇测试与EIA、FIA、FPIA和各种ria之间的方法比较研究产生了可接受的一致性和一致性结果。在新的皮质醇测定中使用的抗体的低交叉反应性被观察到与皮质醇的前体或代谢物。特别是地塞米松没有交叉反应。然而,强的松、6-甲基强的松和皮质酮表现出交叉反应。未观察到内源性干扰的限制。CEDIA皮质醇测定允许精确,快速和充分特异性的皮质醇测定。此外,它具有非放射性分析的优点,可以结合常规临床化学在勃林格曼海姆/日立分析仪上方便地进行。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
[Days of Intensive Medicine-Transplantation. Wien, 2-4 February 1995. Abstracts]. Laboratory Medicine in Diagnosis and Treatment. European Society of Clinical Pathology (SEPaC) seminar-congress. Vienna, Austria, May 22-27, 1995. Abstracts. [Metabolic disturbances and nutrition of the intensive care patient. Vienna, 24-26 February 1994. Abstracts]. [13th Austrian Geriatrics Congress on Healthy Aging. Bad Hofgastein, 19-25 March 1994. Abstracts]. [Alarm plan BLUE--a concept for managing mass emergencies in emergency ambulatory care of the new Vienna general hospital].
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1