Finger-force measurement-device for hand rehabilitation

S. Olandersson, H. Lundqvist, M. Bengtsson, M. Lundahl, A. Baerveldt, M. Hilliges
{"title":"Finger-force measurement-device for hand rehabilitation","authors":"S. Olandersson, H. Lundqvist, M. Bengtsson, M. Lundahl, A. Baerveldt, M. Hilliges","doi":"10.1109/ICORR.2005.1501069","DOIUrl":null,"url":null,"abstract":"The purpose was to develop an extension fingerforce measurement device, and investigate the intraindividual repeatability. The design of the measuring device allows single finger force and whole hand measurements, and the repeatability error on extension finger forces was measured, both on the whole hand, as well as on individual fingers. The tests showed that a repeatability error of less then 15 % can be achieved for single finger measurements and less then 21 % for whole hand measurements.","PeriodicalId":131431,"journal":{"name":"9th International Conference on Rehabilitation Robotics, 2005. ICORR 2005.","volume":"98 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2005-08-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"32","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"9th International Conference on Rehabilitation Robotics, 2005. ICORR 2005.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICORR.2005.1501069","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 32

Abstract

The purpose was to develop an extension fingerforce measurement device, and investigate the intraindividual repeatability. The design of the measuring device allows single finger force and whole hand measurements, and the repeatability error on extension finger forces was measured, both on the whole hand, as well as on individual fingers. The tests showed that a repeatability error of less then 15 % can be achieved for single finger measurements and less then 21 % for whole hand measurements.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
用于手部康复的指力测量装置
目的是开发一种扩展指力测量装置,并研究个体内可重复性。测量装置的设计允许单指力和全手力的测量,并测量了整个手和单个手指上伸指力的重复性误差。实验表明,单指测量的重复性误差小于15%,全手测量的重复性误差小于21%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
A dual input device for self-assisted control of a virtual pendulum Realizing a posture-based wearable antigravity muscles support system for lower extremities Adjustable robotic tendon using a 'Jack Spring'/spl trade/ A 3-D rehabilitation system for upper limbs developed in a 5-year NEDO project and its clinical testing A motorized gravity compensation mechanism used for active rehabilitation of upper limbs
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1