H. Schwab, U. Heinemann, A. Beck, H. Ebert, J. Fricke
{"title":"Prediction of Service Life for Vacuum Insulation Panels with Fumed Silica Kernel and Foil Cover","authors":"H. Schwab, U. Heinemann, A. Beck, H. Ebert, J. Fricke","doi":"10.1177/1097196305051894","DOIUrl":null,"url":null,"abstract":"For vacuum insulation panels (VIPs) with fumed silica kernels and foils as cover, a calculation model is developed to predict the service life. It is defined as the period during which the thermal conductivity of the VIP has risen 50% due to infusion of air and moisture. Two panel sizes, 50 ×50 × 1 cm3 and 100 × 100 × 2 cm3 are considered. For VIPs with laminated aluminum foils, calculated service lives of many decades are determined. For VIPs with aluminum-coated multilayer foils, shorter service lives still above 20 are calculated. This is due to the higher water vapor transmission through the Al-coated multilayer foils (compared to laminated Al foil) and the humidity-related increase in thermal conductivity. Overall, our model predicts service lives, which are large enough for applications of VIPs in buildings. An open question that remains is the long-term stability of the foil cover.","PeriodicalId":435154,"journal":{"name":"Journal of Thermal Envelope and Building Science","volume":"25 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2005-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"62","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Thermal Envelope and Building Science","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/1097196305051894","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 62
Abstract
For vacuum insulation panels (VIPs) with fumed silica kernels and foils as cover, a calculation model is developed to predict the service life. It is defined as the period during which the thermal conductivity of the VIP has risen 50% due to infusion of air and moisture. Two panel sizes, 50 ×50 × 1 cm3 and 100 × 100 × 2 cm3 are considered. For VIPs with laminated aluminum foils, calculated service lives of many decades are determined. For VIPs with aluminum-coated multilayer foils, shorter service lives still above 20 are calculated. This is due to the higher water vapor transmission through the Al-coated multilayer foils (compared to laminated Al foil) and the humidity-related increase in thermal conductivity. Overall, our model predicts service lives, which are large enough for applications of VIPs in buildings. An open question that remains is the long-term stability of the foil cover.