{"title":"Comparison of different rubber stoppers; the effect of sterilization on the number of particles released.","authors":"J P Mannermaa, E Muttonen, J Yliruusi, A Juppo","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>The effect of sterilization on the number of particles released from five different types of rubber stoppers, as well as on their surface roughness and elemental composition before and after sterilization is described. The stoppers were immersed in 200 ml of 0.9% sodium chloride solution in conical flasks. The number of particles released into the sodium chloride solution was measured by Coulter Counter. The surface roughness and the elemental composition of the stoppers were determined by SEM/EDX. All measurements were made both before and after sterilization at 121 degrees C to F0 15 mins. The number of particles released from a stopper during sterilization varies considerably between different stoppers and even between different batches of the same stopper. The only non-siliconized stopper in this study performed well. The absence of surface siliconization may have contributed to this performance. The scanning electron micrographs revealed well the differences in the surface roughness of the stoppers. The sterilization generally increases the surface roughness of the samples. The x-ray microanalysis revealed that the elemental composition of the stoppers may vary not only between different types of stoppers but also between different batches of the same stopper.</p>","PeriodicalId":16667,"journal":{"name":"Journal of parenteral science and technology : a publication of the Parenteral Drug Association","volume":"46 3","pages":"73-7"},"PeriodicalIF":0.0000,"publicationDate":"1992-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of parenteral science and technology : a publication of the Parenteral Drug Association","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
The effect of sterilization on the number of particles released from five different types of rubber stoppers, as well as on their surface roughness and elemental composition before and after sterilization is described. The stoppers were immersed in 200 ml of 0.9% sodium chloride solution in conical flasks. The number of particles released into the sodium chloride solution was measured by Coulter Counter. The surface roughness and the elemental composition of the stoppers were determined by SEM/EDX. All measurements were made both before and after sterilization at 121 degrees C to F0 15 mins. The number of particles released from a stopper during sterilization varies considerably between different stoppers and even between different batches of the same stopper. The only non-siliconized stopper in this study performed well. The absence of surface siliconization may have contributed to this performance. The scanning electron micrographs revealed well the differences in the surface roughness of the stoppers. The sterilization generally increases the surface roughness of the samples. The x-ray microanalysis revealed that the elemental composition of the stoppers may vary not only between different types of stoppers but also between different batches of the same stopper.
描述了灭菌对五种不同类型橡胶塞释放颗粒数量的影响,以及灭菌前后橡胶塞表面粗糙度和元素组成的影响。将瓶塞浸入200 ml 0.9%氯化钠溶液中,置于锥形烧瓶中。用库尔特计数器测量释放到氯化钠溶液中的颗粒数。用SEM/EDX分析了堵头的表面粗糙度和元素组成。所有测量均在121℃至F0 15 min灭菌前后进行。在灭菌过程中,从一个瓶塞释放的颗粒数量在不同的瓶塞之间,甚至在同一瓶塞的不同批次之间,变化很大。本研究中唯一的非硅化塞表现良好。表面硅化的缺失可能促成了这种性能。扫描电镜很好地显示了两种塞的表面粗糙度差异。灭菌通常会增加样品的表面粗糙度。x射线微量分析表明,不同类型的堵塞器,不同批次的同一堵塞器,其元素组成可能存在差异。