{"title":"Maximum power point tracking issues in control of a low power photovoltaic (PV) module","authors":"L. Rao, S. Gairola","doi":"10.1109/ENERGYECONOMICS.2015.7235091","DOIUrl":null,"url":null,"abstract":"The main challenge in control of photovoltaic (PV) power system is to operate at maximum efficiency. The I-V characteristics of PV system are non-linear, which makes it difficult to track the maximum power at varying Insolation and temperature. In this paper a 50W photovoltaic module based system is investigated for its control characteristics. The operating characteristics is studied with the focus on control of boost converter to achieve maximum power point tracking by Perturbation and Observation method uniquely used with PI controller. The performance analysis of this system based model is simulated and presented for MPP operation by applying the control technique to a boost converter highlighting the issues in its control. The simulation results are obtained and plotted for varying insolation level between 50 % and 100 % for validation.","PeriodicalId":130355,"journal":{"name":"2015 International Conference on Energy Economics and Environment (ICEEE)","volume":"329 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-03-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 International Conference on Energy Economics and Environment (ICEEE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ENERGYECONOMICS.2015.7235091","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

The main challenge in control of photovoltaic (PV) power system is to operate at maximum efficiency. The I-V characteristics of PV system are non-linear, which makes it difficult to track the maximum power at varying Insolation and temperature. In this paper a 50W photovoltaic module based system is investigated for its control characteristics. The operating characteristics is studied with the focus on control of boost converter to achieve maximum power point tracking by Perturbation and Observation method uniquely used with PI controller. The performance analysis of this system based model is simulated and presented for MPP operation by applying the control technique to a boost converter highlighting the issues in its control. The simulation results are obtained and plotted for varying insolation level between 50 % and 100 % for validation.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
低功率光伏模块控制中的最大功率点跟踪问题
光伏发电系统控制面临的主要挑战是如何使系统以最高效率运行。光伏系统的I-V特性是非线性的,这使得在不同日照和温度下的最大功率难以跟踪。本文研究了50W光伏组件系统的控制特性。研究了升压变换器的工作特性,重点研究了升压变换器的控制,利用PI控制器特有的摄动和观测方法实现最大功率点跟踪。通过将该控制技术应用于升压变换器,对该系统的性能进行了仿真分析,并指出了其控制中存在的问题。在50%和100%的日照水平变化情况下,得到了模拟结果并绘制了图以验证。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Letter of acquisition Smart grid implementation in India — A case study of Puducherry Pilot Project, India One hour ahead load forecast of PJM electricity market & UPPCL Comparative study of optimization algorithms for enhancement of small signal stability by designing PSS for multi-machine power system Aging leader and challenger based PSO for harmonic mitigation using SAPF
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1