Impact Analysis of Double Fed Induction Generator Low-Voltage Ride-Through on the Switches of the Back-to-Back Converters

V. R. F. B. Souza, L. S. Barros, F. Costa, Guilherme P. Silva
{"title":"Impact Analysis of Double Fed Induction Generator Low-Voltage Ride-Through on the Switches of the Back-to-Back Converters","authors":"V. R. F. B. Souza, L. S. Barros, F. Costa, Guilherme P. Silva","doi":"10.1109/PESGM41954.2020.9281798","DOIUrl":null,"url":null,"abstract":"The expansion of wind energy conversion systems (WECS) is largely due to the advancements of power electronics devices, especially in terms of processed power levels as well as robustness in grid fault situations. In this sense, the power converters participate in the conditioning and control of the power delivered by the generators, requiring an analysis of the impact caused by situations that lead to possible damages or lifetime shortening due to abnormal operations. Considering this problem, in this paper a case study is performed in order to evaluate the impact of the double fed induction generator (DFIG) low-voltage ride-through (LVRT) on the switches of the back-to-back converters. For this purpose, modeling of the DFIG-based WECS has been performed in MatLab/Simulink, including a linear model for the converter switches, which are of insulated gate bipolar transistor (IGBT) type. The analysis presents the main impacts on the IGBT internal currents and voltages under symmetrical and asymmetrical grid faults, making possible to guide the application of methods and techniques to minimize the impacts caused to the converters.","PeriodicalId":106476,"journal":{"name":"2020 IEEE Power & Energy Society General Meeting (PESGM)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2020-08-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 IEEE Power & Energy Society General Meeting (PESGM)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PESGM41954.2020.9281798","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The expansion of wind energy conversion systems (WECS) is largely due to the advancements of power electronics devices, especially in terms of processed power levels as well as robustness in grid fault situations. In this sense, the power converters participate in the conditioning and control of the power delivered by the generators, requiring an analysis of the impact caused by situations that lead to possible damages or lifetime shortening due to abnormal operations. Considering this problem, in this paper a case study is performed in order to evaluate the impact of the double fed induction generator (DFIG) low-voltage ride-through (LVRT) on the switches of the back-to-back converters. For this purpose, modeling of the DFIG-based WECS has been performed in MatLab/Simulink, including a linear model for the converter switches, which are of insulated gate bipolar transistor (IGBT) type. The analysis presents the main impacts on the IGBT internal currents and voltages under symmetrical and asymmetrical grid faults, making possible to guide the application of methods and techniques to minimize the impacts caused to the converters.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
双馈感应发电机低压穿越对背靠背变流器开关的影响分析
风能转换系统(WECS)的发展很大程度上是由于电力电子设备的进步,特别是在处理功率水平和电网故障情况下的鲁棒性方面。从这个意义上说,电源变流器参与调节和控制发电机提供的电力,需要分析由于异常运行而导致可能损坏或缩短寿命的情况所造成的影响。考虑到这一问题,本文进行了一个案例研究,以评估双馈感应发电机(DFIG)低压穿越(LVRT)对背靠背变流器开关的影响。为此,在MatLab/Simulink中对基于dfig的WECS进行了建模,其中包括绝缘栅双极晶体管(IGBT)型转换开关的线性模型。分析了对称和不对称电网故障对IGBT内部电流和电压的主要影响,为减小对变流器影响的方法和技术的应用提供了指导。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Distributed Framework for P2P Energy Sharing among Building Prosumers using Stackelberg Game Voltage Sensitivity Analysis Based PV Hosting Capacity Evaluation Considering Uncertainties Synchronous Phasor Data Compression Based on Swing Door Trending in WAMS Analytical Method for Eliminating the Impact of External Interference on Soil Resistivity Measurements Effects of Aging and Temperature on Supercapacitor Charge Capacity
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1