Small helical magnetic flux compression generators: Experiments and analysis.

P. Appelgren, G. Bjarnholt, M. Elfsberg, T. Hurtig, A. Larsson, S. E. Nyholm
{"title":"Small helical magnetic flux compression generators: Experiments and analysis.","authors":"P. Appelgren, G. Bjarnholt, M. Elfsberg, T. Hurtig, A. Larsson, S. E. Nyholm","doi":"10.1109/PPPS.2007.4346020","DOIUrl":null,"url":null,"abstract":"This paper presents experimental results with helical magnetic flux-compression generators (FCGs). FCGs convert the chemical energy bond in explosives into electric energy. The generator had an initial inductance of 23 μH and was operated into a load of 0.2 μH. The generator is charged with 0.27 kg of high-explosives (PBXN-5). Various types of diagnostics were used to monitor the operation of the generator, including current probes, optical fibres, and piezo gauges. The results are analysed and the expansion of the armature compared with hydrodynamic simulations.","PeriodicalId":275106,"journal":{"name":"2007 16th IEEE International Pulsed Power Conference","volume":"53 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2007-06-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2007 16th IEEE International Pulsed Power Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PPPS.2007.4346020","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

This paper presents experimental results with helical magnetic flux-compression generators (FCGs). FCGs convert the chemical energy bond in explosives into electric energy. The generator had an initial inductance of 23 μH and was operated into a load of 0.2 μH. The generator is charged with 0.27 kg of high-explosives (PBXN-5). Various types of diagnostics were used to monitor the operation of the generator, including current probes, optical fibres, and piezo gauges. The results are analysed and the expansion of the armature compared with hydrodynamic simulations.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
小型螺旋磁通压缩发生器:实验与分析。
本文介绍了螺旋磁通压缩发生器的实验结果。FCGs将炸药中的化学键转化为电能。发电机的初始电感为23 μH,运行在0.2 μH的负载上。发生器充装0.27千克高爆药(PBXN-5)。各种类型的诊断被用来监测发电机的运行,包括电流探头、光纤和压电计。对结果进行了分析,并与水动力模拟结果进行了比较。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Dissipative instability under weak beam-plasma coupling Inductive heating of materials for the study of high-temperature mechanical properties. Application of a self-breakdown hydrogen spark gap switch on high power pulse modulator Discharge current and current of supershort avalanche E-beam at volume nanosecond discharge in non-uniform electric field Vertical dust particle chains - mass and charge measurements
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1