Comparación de la fuerza adhesiva de 2 sistemas de cementos de resina en diferentes regiones radiculares en la cementación de postes de fibra

Patricio Vildósola Grez , Pablo Angel Aguirre , Andrea Pino Garrido , Patricia Cisternas Pinto , Emilio Diaz Durán , Osmir Batista de Oliveira junior , Jose Roberto Cury Saad , Marcelo Bader Mattar
{"title":"Comparación de la fuerza adhesiva de 2 sistemas de cementos de resina en diferentes regiones radiculares en la cementación de postes de fibra","authors":"Patricio Vildósola Grez ,&nbsp;Pablo Angel Aguirre ,&nbsp;Andrea Pino Garrido ,&nbsp;Patricia Cisternas Pinto ,&nbsp;Emilio Diaz Durán ,&nbsp;Osmir Batista de Oliveira junior ,&nbsp;Jose Roberto Cury Saad ,&nbsp;Marcelo Bader Mattar","doi":"10.1016/j.piro.2015.02.001","DOIUrl":null,"url":null,"abstract":"<div><p>Loosening is the most common failure of fiber posts, mainly due to complex adhesion within the root canal. The main objective of this study was to determine if significant differences in adhesive resistance, using the push-out test, in the cementation of fiber posts with RelyX U-200<sup>®</sup> (U200) and Core Paste XP<sup>®</sup> (CPX) in different root regions.</p></div><div><h3>Material and methods</h3><p>A selection of 40 premolars were sectioned 15<!--> <!-->mm from the apex, treated endodontically and then randomly divided in two groups of 20, using an Exacto translucent fiber post with U200 and CPX, respectively. After 24<!--> <!-->hours, each sample was sectioned into cervical, middle and apical. The test push-out test was performed using a Tinius Olsen HK5-S machine to quantify the adhesive strength in Mega Pascals. The test Shapiro-Wilk, two-factor Anova and Tukey tests were used with a significance level of 95%</p></div><div><h3>Results</h3><p>There were no significant differences between the cements (<em>P</em> <!-->=<!--> <!-->.457) but if there was difference when comparing the type of cement and region. CPX showed a value significantly higher in the cervical third (<em>P</em> <!-->&lt;<!--> <!-->.05), while U200 presented a value significantly higher in the apical third (<em>P</em> <!-->&lt;<!--> <!-->.05).</p></div><div><h3>Conclusions</h3><p>There was no significant difference in the value of the adhesive strength in the comparison between U200 and CXP, however there was a higher value of CXP at cervical and U200 at apical level.</p></div>","PeriodicalId":21203,"journal":{"name":"Revista clínica de periodoncia, implantología y rehabilitación oral","volume":"8 1","pages":"Pages 38-44"},"PeriodicalIF":0.0000,"publicationDate":"2015-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/j.piro.2015.02.001","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Revista clínica de periodoncia, implantología y rehabilitación oral","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0718539115000063","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

Loosening is the most common failure of fiber posts, mainly due to complex adhesion within the root canal. The main objective of this study was to determine if significant differences in adhesive resistance, using the push-out test, in the cementation of fiber posts with RelyX U-200® (U200) and Core Paste XP® (CPX) in different root regions.

Material and methods

A selection of 40 premolars were sectioned 15 mm from the apex, treated endodontically and then randomly divided in two groups of 20, using an Exacto translucent fiber post with U200 and CPX, respectively. After 24 hours, each sample was sectioned into cervical, middle and apical. The test push-out test was performed using a Tinius Olsen HK5-S machine to quantify the adhesive strength in Mega Pascals. The test Shapiro-Wilk, two-factor Anova and Tukey tests were used with a significance level of 95%

Results

There were no significant differences between the cements (P = .457) but if there was difference when comparing the type of cement and region. CPX showed a value significantly higher in the cervical third (P < .05), while U200 presented a value significantly higher in the apical third (P < .05).

Conclusions

There was no significant difference in the value of the adhesive strength in the comparison between U200 and CXP, however there was a higher value of CXP at cervical and U200 at apical level.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
两种树脂胶结体系在纤维桩胶结不同根区粘结强度的比较
松动是纤维桩最常见的故障,主要是由于根管内复杂的粘连。本研究的主要目的是通过推出试验,确定在不同根区使用RelyX U-200®(U200)和Core Paste XP®(CPX)的纤维桩胶结中粘接性是否存在显著差异。材料与方法选择40颗前磨牙,在距牙尖15mm处进行根管治疗,随机分为两组,每组20颗,分别使用含有U200和CPX的Exacto半透明纤维桩。24小时后,将每个标本切片为颈、中、根尖。测试推出测试使用Tinius Olsen HK5-S机器进行,以量化以兆帕斯卡为单位的粘合强度。采用夏皮罗-威尔克检验、双因素方差分析和Tukey检验,显著性水平为95%。结果两种骨水泥间无显著性差异(P = 0.457),但在骨水泥类型和区域间有显著性差异。CPX值在颈椎第三节明显升高(P <.05),而U200在顶端三分之一的值显著更高(P <. 05)。结论U200与CXP的粘接强度值差异无统计学意义,但CXP在颈椎处的粘接强度高于U200在根尖处的粘接强度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Flujo salival y caries radicular en adultos mayores autovalentes Necesidad de tratamiento periodontal en adolescentes de 12 años de colegios municipalizados en Valdivia–Chile 2014: estudio transversal Impacto de la hipomineralización incisivo molar en la experiencia de caries en escolares de 6-12 años en Santiago, Chile Repigmentación melánica de la melanosis gingival. Revisión sistemática Marsupialización modificada de ránula gigante intraoral: reporte de caso
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1