{"title":"The Influence of Sample Mass and Flow Velocity on Performance in Preparative Column Liquid Chromatography","authors":"V. R. Meyer","doi":"10.1080/01496398708057619","DOIUrl":null,"url":null,"abstract":"Abstract The H/u curves of two HPLC columns of 10 mm i.d., filled with silica of a particle diameter of 5 and 25–40 μm, respectively, have been determined at various amounts of injected sample. Indications of mass overload, Le, peak broadening, occur at a sample load of 10 μg/g for the column with 5 μm silica but not until 100 μg/g for the column with coarse stationary phase. Although H values increase markedly with higher sample mass, the slopes of the H/u curves remain almost constant on both columns up to samples of 1 mg/g. This means the relative increase of the plate height with increasing flow velocity becomes nearly negligible under conditions of moderate mass overload. However, by increasing the sample load up to 5 or 10 mg/g, the H/u curves show a dramatic increase of slope: at high mass overload the mobile phase flow rate cannot be increased without a remarkable decrease in column performance.","PeriodicalId":184327,"journal":{"name":"Preparative-Scale Chromatography","volume":"35 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1987-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Preparative-Scale Chromatography","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/01496398708057619","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1
Abstract
Abstract The H/u curves of two HPLC columns of 10 mm i.d., filled with silica of a particle diameter of 5 and 25–40 μm, respectively, have been determined at various amounts of injected sample. Indications of mass overload, Le, peak broadening, occur at a sample load of 10 μg/g for the column with 5 μm silica but not until 100 μg/g for the column with coarse stationary phase. Although H values increase markedly with higher sample mass, the slopes of the H/u curves remain almost constant on both columns up to samples of 1 mg/g. This means the relative increase of the plate height with increasing flow velocity becomes nearly negligible under conditions of moderate mass overload. However, by increasing the sample load up to 5 or 10 mg/g, the H/u curves show a dramatic increase of slope: at high mass overload the mobile phase flow rate cannot be increased without a remarkable decrease in column performance.