A Method for Selecting Harmonic Monitoring Points Considering Correlation between Voltage Value and Harmonic Distortion Rate

Hongtao Sheng, Huaying Zhang, Qing Wang, Jun Tao, Qianlong Zhu
{"title":"A Method for Selecting Harmonic Monitoring Points Considering Correlation between Voltage Value and Harmonic Distortion Rate","authors":"Hongtao Sheng, Huaying Zhang, Qing Wang, Jun Tao, Qianlong Zhu","doi":"10.1109/CEEPE58418.2023.10165947","DOIUrl":null,"url":null,"abstract":"The harmonic distortion level of nonlinear load in distribution network has been widely concerned. At the same time, the monitoring of distribution system is insufficient, and it is difficult to reflect the overall harmonic level by setting fewer harmonic monitoring points. In order to solve this problem, this paper proposes a method to determine harmonic monitoring points by using voltage value according to the correlation between voltage value and harmonic distortion rate. The proposed method for setting harmonic monitoring points uses the fundamental voltage value of each bus collected from traditional smart meters. By comparing the correlation between fundamental voltage index and harmonic voltage distortion rate, it is found that the fundamental voltage index has a strong correlation with harmonic voltage distortion rate. It is proposed to use Pearson correlation coefficient matrix of fundamental voltage index to determine harmonic monitoring nodes through optimization algorithm. In this paper, IEEE-14 node is used to verify this method. The results show that the harmonic level of the whole distribution network can be reflected by setting a few harmonic monitoring points.","PeriodicalId":431552,"journal":{"name":"2023 6th International Conference on Energy, Electrical and Power Engineering (CEEPE)","volume":"72 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-05-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2023 6th International Conference on Energy, Electrical and Power Engineering (CEEPE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CEEPE58418.2023.10165947","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The harmonic distortion level of nonlinear load in distribution network has been widely concerned. At the same time, the monitoring of distribution system is insufficient, and it is difficult to reflect the overall harmonic level by setting fewer harmonic monitoring points. In order to solve this problem, this paper proposes a method to determine harmonic monitoring points by using voltage value according to the correlation between voltage value and harmonic distortion rate. The proposed method for setting harmonic monitoring points uses the fundamental voltage value of each bus collected from traditional smart meters. By comparing the correlation between fundamental voltage index and harmonic voltage distortion rate, it is found that the fundamental voltage index has a strong correlation with harmonic voltage distortion rate. It is proposed to use Pearson correlation coefficient matrix of fundamental voltage index to determine harmonic monitoring nodes through optimization algorithm. In this paper, IEEE-14 node is used to verify this method. The results show that the harmonic level of the whole distribution network can be reflected by setting a few harmonic monitoring points.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
考虑电压值与谐波失真率相关性的谐波监测点选择方法
配电网中非线性负荷的谐波失真程度一直受到广泛关注。同时,对配电系统的监测不足,通过设置较少的谐波监测点难以反映整体谐波水平。为了解决这一问题,本文提出了一种根据电压值与谐波失真率的相关性,利用电压值确定谐波监测点的方法。该方法利用传统智能电表采集的各母线基电压值设置谐波监测点。通过比较基频电压指数与谐波电压失真率的相关性,发现基频电压指数与谐波电压失真率有很强的相关性。提出通过优化算法,利用基本电压指数的Pearson相关系数矩阵确定谐波监测节点。本文使用IEEE-14节点对该方法进行验证。结果表明,通过设置几个谐波监测点,可以反映整个配电网的谐波水平。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Fault Detection Method of Infrared Image for Circulating Pump Motor in Valve Cooling System Based on Improved YOLOv3 High Renewable Penetration Development Planning under System Inertia Constraints A Robust OPF Model with Consideration of Reactive Power and Voltage Magnitude A Numerical Study on Rime Ice Accretion Characteristics for Wind Turbine Blades Research on Optimal Allocation Method of Energy Storage Devices for Coordinated Wind and Solar Power Generation
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1