C. Gao, M. An, Guangming Huang, Xing Huang, Y. Mei, Quan Sun, Xiangming Sun, L. Xiao, P. Yang
{"title":"A Low-Noise Charge-Sensitive Amplifier for Gainless Charge Readout in High-Pressure Gas TPC","authors":"C. Gao, M. An, Guangming Huang, Xing Huang, Y. Mei, Quan Sun, Xiangming Sun, L. Xiao, P. Yang","doi":"10.22323/1.343.0083","DOIUrl":null,"url":null,"abstract":"TWEPP 2018Topical Workshop on Electronics for Particle Physics. https://indico.cern.ch/event/697988/contributions/3056035/ We present a low-noise Charge-Sensitive Amplifier (CSA) manufactured in a standard 0.35 μm CMOS process. The CSA is part of an integrated sensor named Topmetal-S, with an array of which, forms a charge readout plane in a high-pressure gaseous Time Projection Chamber (TPC) for 0νββ search. A single-ended folded cascode amplifier with a 73 dB open-loop gain and 340 MHz gain-bandwidth product forms the main amplification stage in this CSA. Measurements show that the conversion gain of the CSA with a 3 fF feedback capacitor is 168 mV/fC. The equivalent noise charge of the CSA after a trapezoidal pulse shaper is 28.7erms with a 5 pF detector capacitance. Introduction Topmetal sensor for a next-generation high-pressure gaseous (TPC) to search for neutrinoless double-beta decay (0υββ): Ø Topmetal sensor advantage: directly collecting ionization charges without gas-electron multiplication Ø Energy resolution: < 1% FWHM Ø Charge Collection Electrode : 1 mm diameter Ø Pitch: 5 mm Ø 105 sensors for a large plane","PeriodicalId":400748,"journal":{"name":"Proceedings of Topical Workshop on Electronics for Particle Physics — PoS(TWEPP2018)","volume":"16 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-05-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"9","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of Topical Workshop on Electronics for Particle Physics — PoS(TWEPP2018)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.22323/1.343.0083","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 9
Abstract
TWEPP 2018Topical Workshop on Electronics for Particle Physics. https://indico.cern.ch/event/697988/contributions/3056035/ We present a low-noise Charge-Sensitive Amplifier (CSA) manufactured in a standard 0.35 μm CMOS process. The CSA is part of an integrated sensor named Topmetal-S, with an array of which, forms a charge readout plane in a high-pressure gaseous Time Projection Chamber (TPC) for 0νββ search. A single-ended folded cascode amplifier with a 73 dB open-loop gain and 340 MHz gain-bandwidth product forms the main amplification stage in this CSA. Measurements show that the conversion gain of the CSA with a 3 fF feedback capacitor is 168 mV/fC. The equivalent noise charge of the CSA after a trapezoidal pulse shaper is 28.7erms with a 5 pF detector capacitance. Introduction Topmetal sensor for a next-generation high-pressure gaseous (TPC) to search for neutrinoless double-beta decay (0υββ): Ø Topmetal sensor advantage: directly collecting ionization charges without gas-electron multiplication Ø Energy resolution: < 1% FWHM Ø Charge Collection Electrode : 1 mm diameter Ø Pitch: 5 mm Ø 105 sensors for a large plane