Electric field close to lightning channel in the presence of current reflections from the ground

J. Cvetic, M. Ignjatović, M. Tausanovic, N. Mijajlovic, D. Pavlović, F. Heidler
{"title":"Electric field close to lightning channel in the presence of current reflections from the ground","authors":"J. Cvetic, M. Ignjatović, M. Tausanovic, N. Mijajlovic, D. Pavlović, F. Heidler","doi":"10.1109/ICLP.2016.7791398","DOIUrl":null,"url":null,"abstract":"Appearance of an overcompensated positive electric field in most vertical field measurements performed very close to the channel core is explained using the extended generalized traveling current source (extended GTCS) return stroke model with current reflections from the ground. New effects in the corona sheath due to the reflection of current pulses have been noted and taken into account. The channel-base current is separated into two components. The first current component is fast and with a greater peak value, while the second component is slower and with a lower peak. We've analyzed a return stroke for which the channel-base current and the electric field waveform very close to the triggered lightning are measured simultaneously. A new charging function is calculated according to the extended GTCS model, as well as the value of the ground reflection coefficient for the analyzed stroke. On one hand, new results are obtained through calculations of the channel charging function. On the other, the calculated values of the ground reflection coefficient confirm the results reported in other independent studies performed in natural or laboratory conditions. Finally, the concept of the extended GTCS model, that takes into account current pulse reflections from the ground, is proved to be correct.","PeriodicalId":373744,"journal":{"name":"2016 33rd International Conference on Lightning Protection (ICLP)","volume":"84 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 33rd International Conference on Lightning Protection (ICLP)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICLP.2016.7791398","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Appearance of an overcompensated positive electric field in most vertical field measurements performed very close to the channel core is explained using the extended generalized traveling current source (extended GTCS) return stroke model with current reflections from the ground. New effects in the corona sheath due to the reflection of current pulses have been noted and taken into account. The channel-base current is separated into two components. The first current component is fast and with a greater peak value, while the second component is slower and with a lower peak. We've analyzed a return stroke for which the channel-base current and the electric field waveform very close to the triggered lightning are measured simultaneously. A new charging function is calculated according to the extended GTCS model, as well as the value of the ground reflection coefficient for the analyzed stroke. On one hand, new results are obtained through calculations of the channel charging function. On the other, the calculated values of the ground reflection coefficient confirm the results reported in other independent studies performed in natural or laboratory conditions. Finally, the concept of the extended GTCS model, that takes into account current pulse reflections from the ground, is proved to be correct.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
地面反射电流时靠近闪电通道的电场
在非常接近通道核心的大多数垂直场测量中,使用扩展广义旅行电流源(扩展GTCS)返回行程模型解释了过度补偿的正电场的出现,该模型具有来自地面的电流反射。由于电流脉冲的反射,日冕鞘中的新效应已经被注意到并考虑到。通道基电流被分成两个分量。第一个电流分量快,峰值大,而第二个电流分量慢,峰值低。我们分析了一个回路,同时测量了通道基电流和非常接近触发闪电的电场波形。根据扩展后的GTCS模型,计算了新的装药函数,并计算了分析行程的地面反射系数值。一方面,通过通道充电函数的计算得到了新的结果。另一方面,地面反射系数的计算值证实了在自然或实验室条件下进行的其他独立研究报告的结果。最后,验证了考虑地面脉冲电流反射的扩展GTCS模型概念的正确性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Experimental and theoretical evaluation of aluminium deflection due to lightning strikes Degradation characteristics on MOV of surge arrester used for 6.6kV power distribution line Lightning protection of a temporary structure in open area Lightning performance of EHV and UHV overhead transmission Lines in China southern power grid Research of influence pattern of lightning current on impulse characteristic of ground device for pole and tower
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1