{"title":"Model-based voltage calculation for inverters with small DC-Link capacitance","authors":"M. von Zimmermann, A. Kuskov, B. Piepenbreier","doi":"10.1109/EDPC.2011.6085566","DOIUrl":null,"url":null,"abstract":"Employing only a small capacitance in the DC-link of an adjustable speed drive (ASD) enables the replacement of electrolytic capacitors with film capacitors. Unfortunately, in combination with a diode bridge rectifier the DC-link voltage exhibits a significant six-pulse ripple. By measuring the DC-link voltage and providing the load side control with its value as widely done, this ripple can be compensated. In the following, a method is presented calculating the varying DC-link voltage by referring exclusively to the transfer function of the rectifier. This way, the DC-link voltage sensor can be omitted. Additionally, a partially damped mains filter is implemented to reduce line current oscillations. Experimental results verify the suitability of both the filter design and the model-based control.","PeriodicalId":333533,"journal":{"name":"2011 1st International Electric Drives Production Conference","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2011-11-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 1st International Electric Drives Production Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EDPC.2011.6085566","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Employing only a small capacitance in the DC-link of an adjustable speed drive (ASD) enables the replacement of electrolytic capacitors with film capacitors. Unfortunately, in combination with a diode bridge rectifier the DC-link voltage exhibits a significant six-pulse ripple. By measuring the DC-link voltage and providing the load side control with its value as widely done, this ripple can be compensated. In the following, a method is presented calculating the varying DC-link voltage by referring exclusively to the transfer function of the rectifier. This way, the DC-link voltage sensor can be omitted. Additionally, a partially damped mains filter is implemented to reduce line current oscillations. Experimental results verify the suitability of both the filter design and the model-based control.