Model-based voltage calculation for inverters with small DC-Link capacitance

M. von Zimmermann, A. Kuskov, B. Piepenbreier
{"title":"Model-based voltage calculation for inverters with small DC-Link capacitance","authors":"M. von Zimmermann, A. Kuskov, B. Piepenbreier","doi":"10.1109/EDPC.2011.6085566","DOIUrl":null,"url":null,"abstract":"Employing only a small capacitance in the DC-link of an adjustable speed drive (ASD) enables the replacement of electrolytic capacitors with film capacitors. Unfortunately, in combination with a diode bridge rectifier the DC-link voltage exhibits a significant six-pulse ripple. By measuring the DC-link voltage and providing the load side control with its value as widely done, this ripple can be compensated. In the following, a method is presented calculating the varying DC-link voltage by referring exclusively to the transfer function of the rectifier. This way, the DC-link voltage sensor can be omitted. Additionally, a partially damped mains filter is implemented to reduce line current oscillations. Experimental results verify the suitability of both the filter design and the model-based control.","PeriodicalId":333533,"journal":{"name":"2011 1st International Electric Drives Production Conference","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2011-11-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 1st International Electric Drives Production Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EDPC.2011.6085566","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Employing only a small capacitance in the DC-link of an adjustable speed drive (ASD) enables the replacement of electrolytic capacitors with film capacitors. Unfortunately, in combination with a diode bridge rectifier the DC-link voltage exhibits a significant six-pulse ripple. By measuring the DC-link voltage and providing the load side control with its value as widely done, this ripple can be compensated. In the following, a method is presented calculating the varying DC-link voltage by referring exclusively to the transfer function of the rectifier. This way, the DC-link voltage sensor can be omitted. Additionally, a partially damped mains filter is implemented to reduce line current oscillations. Experimental results verify the suitability of both the filter design and the model-based control.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于模型的小直流电容逆变器电压计算
在可调速驱动器(ASD)的直流链路中仅使用小电容,就可以用薄膜电容器代替电解电容器。不幸的是,与二极管桥式整流器相结合,直流链路电压表现出显著的六脉冲纹波。通过测量直流链路电压并提供负载侧控制其值,可以补偿这种纹波。在下面,提出了一种方法,计算变化的直流链路电压只参考整流器的传递函数。这样,直流链路电压传感器可以省略。此外,一个部分阻尼的市电滤波器的实施,以减少线路电流振荡。实验结果验证了滤波器设计和基于模型的控制的适用性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Modelling and model based compensation of non-ideal characteristics of two-level voltage source inverters for drive control application High current PCBs - system integration of busbars and electronics Design of compact BLDC drive A new generation of power modules with sinter-technology for the automotive industry New approaches for highly productive laser welding of copper materials
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1