The SEA-Scope: Torque-limited endoscopic joint control for telemanipulation or visual servoing through tendon force control with series elastic actuation

Lorin Fasel, N. Gerig, P. Cattin, G. Rauter
{"title":"The SEA-Scope: Torque-limited endoscopic joint control for telemanipulation or visual servoing through tendon force control with series elastic actuation","authors":"Lorin Fasel, N. Gerig, P. Cattin, G. Rauter","doi":"10.1109/ismr48346.2021.9661497","DOIUrl":null,"url":null,"abstract":"When performing minimally invasive surgeries, surgeons are currently restricted by the rigidity and limited maneuverability of their tools. The tools could be extended by joints to provide additional degrees of freedom. However, manually controlling the movement of distal joints is challenging since the effective interaction forces at the tip are difficult to feel. Therefore, manipulation of distal joints to increase the maneuverability can lead to additional risks for harming the patient. To overcome limited maneuverability while providing inherent safety, we propose a novel concept for minimally invasive tool actuation based on the principle of series elastic actuation. In previous work, we showed successful torque control of an articulated robotic endoscope. In this paper, we extended torque control by high-level position control. We evaluated the position control experimentally for the case of a telemanipulated joint as well as for automatic target following. Automatic target following was achieved with visual servoing, i.e., an image stream from a miniature camera was processed to compute the joint position setpoint. The results showed that accurate and stable position control is feasible with an actuation based on series elastic actuation. Compared to traditional robotic endoscope actuation, which is designed to be as stiff as possible, our approach reduced impact forces and allowed to set the torque limit in the joint as desired. Therefore, torques exerted by the endoscope joint to adjacent structures can be kept within desired limits.","PeriodicalId":405817,"journal":{"name":"2021 International Symposium on Medical Robotics (ISMR)","volume":"677 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-11-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 International Symposium on Medical Robotics (ISMR)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ismr48346.2021.9661497","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

When performing minimally invasive surgeries, surgeons are currently restricted by the rigidity and limited maneuverability of their tools. The tools could be extended by joints to provide additional degrees of freedom. However, manually controlling the movement of distal joints is challenging since the effective interaction forces at the tip are difficult to feel. Therefore, manipulation of distal joints to increase the maneuverability can lead to additional risks for harming the patient. To overcome limited maneuverability while providing inherent safety, we propose a novel concept for minimally invasive tool actuation based on the principle of series elastic actuation. In previous work, we showed successful torque control of an articulated robotic endoscope. In this paper, we extended torque control by high-level position control. We evaluated the position control experimentally for the case of a telemanipulated joint as well as for automatic target following. Automatic target following was achieved with visual servoing, i.e., an image stream from a miniature camera was processed to compute the joint position setpoint. The results showed that accurate and stable position control is feasible with an actuation based on series elastic actuation. Compared to traditional robotic endoscope actuation, which is designed to be as stiff as possible, our approach reduced impact forces and allowed to set the torque limit in the joint as desired. Therefore, torques exerted by the endoscope joint to adjacent structures can be kept within desired limits.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
SEA-Scope:通过串联弹性驱动的肌腱力控制,用于遥控或视觉伺服的扭矩有限的内窥镜关节控制
在进行微创手术时,外科医生目前受到其工具的刚性和有限的可操作性的限制。这些工具可以通过关节进行扩展,以提供额外的自由度。然而,手动控制远端关节的运动是具有挑战性的,因为在尖端的有效相互作用力很难感觉到。因此,通过操纵远端关节来增加可操作性会增加伤害患者的风险。为了在保证固有安全性的同时克服机动性的限制,我们提出了一种基于串联弹性驱动原理的微创工具驱动的新概念。在之前的工作中,我们成功地展示了铰接式机器人内窥镜的扭矩控制。本文通过高级位置控制对转矩控制进行了扩展。我们通过实验评估了远程操纵关节的位置控制以及自动目标跟踪。采用视觉伺服实现自动目标跟踪,即对来自微型摄像机的图像流进行处理,计算关节位置设定值。结果表明,采用基于串联弹性驱动的驱动方式,可以实现精确、稳定的位置控制。传统的机器人内窥镜驱动被设计得尽可能坚硬,与之相比,我们的方法减少了冲击力,并允许根据需要设置关节中的扭矩限制。因此,内窥镜关节对邻近结构施加的扭矩可以保持在期望的范围内。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
MOPS: A Modular and Open Platform for Surgical Robotics Research Lymph Node Detection Using Robot Assisted Electrical Impedance Scanning and an Artificial Neural Network Image-Guided Optimization of Robotic Catheters for Patient-Specific Endovascular Intervention Surgical Skill Evaluation From Robot-Assisted Surgery Recordings Learning Soft-Tissue Simulation from Models and Observation
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1