Je-Wei Lan, I. Huang, Yu-Cheng Lin, Wen-Hui Huang, C. Yeh, Chia-Hsu Hsieh
{"title":"FPW biosensor with low insertion loss for detection of Tetrahydrocannabinol antigen","authors":"Je-Wei Lan, I. Huang, Yu-Cheng Lin, Wen-Hui Huang, C. Yeh, Chia-Hsu Hsieh","doi":"10.1109/TRANSDUCERS.2017.7994368","DOIUrl":null,"url":null,"abstract":"Conventional flexural plate-wave (FPW) devices usually have high insertion loss, so we designed focus-type interdigital transducers (IDTs) that can effectively constrain launched wave energy, and adopted a focus-type silicon-grooved reflective grating structure (RGS) to reduce wave propagation loss. The results reveal that the proposed FPW devices have lower insertion loss (−38.698 dB). Then, we used the improved FPW device to develop a novel FPW-based biosensor for rapid detection of Tetrahydrocannabinol (THC) concentration in human urine by integrating. This FPW-THC biosensor has low detection limit (40 ng/mL), high sensitivity (126.67 cm2/g), and high sensing linearity (R-square=0.916).","PeriodicalId":174774,"journal":{"name":"2017 19th International Conference on Solid-State Sensors, Actuators and Microsystems (TRANSDUCERS)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2017-07-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 19th International Conference on Solid-State Sensors, Actuators and Microsystems (TRANSDUCERS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/TRANSDUCERS.2017.7994368","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Conventional flexural plate-wave (FPW) devices usually have high insertion loss, so we designed focus-type interdigital transducers (IDTs) that can effectively constrain launched wave energy, and adopted a focus-type silicon-grooved reflective grating structure (RGS) to reduce wave propagation loss. The results reveal that the proposed FPW devices have lower insertion loss (−38.698 dB). Then, we used the improved FPW device to develop a novel FPW-based biosensor for rapid detection of Tetrahydrocannabinol (THC) concentration in human urine by integrating. This FPW-THC biosensor has low detection limit (40 ng/mL), high sensitivity (126.67 cm2/g), and high sensing linearity (R-square=0.916).