Xuyang Li, Y. L. Sit, L. Zwirello, M. Jalilvand, T. Zwick
{"title":"An E-field probe based near-field measurement system for on- and in-body antennas","authors":"Xuyang Li, Y. L. Sit, L. Zwirello, M. Jalilvand, T. Zwick","doi":"10.23919/EUMC.2012.6459127","DOIUrl":null,"url":null,"abstract":"For the characterization of the antennas for medical diagnostics or implanted devices, an E-field probe based antenna measurement system is presented here. Since the devices work in the near-field range of the antenna, the near-field measurement of the antennas is performed. A liquid phantom, a mixture from PEG and water, is chosen to emulate different tissues with regards to their dielectric properties. The system is characterized from 0.5 GHz to 5 GHz with pattern measurement both in E- and H-plane of the antennas. The short measured distance of 4-6 cm between two antennas in the liquid phantom is maintained. Benefiting from the positioning system with high accuracy motors and the small size of the probe for capturing the E-fields, the measurement system exhibits an extremely reliable results of the near-field pattern.","PeriodicalId":266910,"journal":{"name":"2012 42nd European Microwave Conference","volume":"17 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"9","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 42nd European Microwave Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.23919/EUMC.2012.6459127","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 9
Abstract
For the characterization of the antennas for medical diagnostics or implanted devices, an E-field probe based antenna measurement system is presented here. Since the devices work in the near-field range of the antenna, the near-field measurement of the antennas is performed. A liquid phantom, a mixture from PEG and water, is chosen to emulate different tissues with regards to their dielectric properties. The system is characterized from 0.5 GHz to 5 GHz with pattern measurement both in E- and H-plane of the antennas. The short measured distance of 4-6 cm between two antennas in the liquid phantom is maintained. Benefiting from the positioning system with high accuracy motors and the small size of the probe for capturing the E-fields, the measurement system exhibits an extremely reliable results of the near-field pattern.