Solution to directional relaying for double circuit line

P. Jena, A. Pradhan
{"title":"Solution to directional relaying for double circuit line","authors":"P. Jena, A. Pradhan","doi":"10.1109/ICEAS.2011.6147079","DOIUrl":null,"url":null,"abstract":"Protection of double circuit line is more complex than the single circuit. Problems associated with directional relaying for double circuit line during close-in fault, cross country fault, load change and with high resistance fault are addressed in this paper. Conventional directional relaying algorithm uses fault voltage and current phasors to derive the decisions and thus, finds its limitation during close-in fault, load change and cross country fault. In this work a directional relaying scheme using fuzzy logic system is proposed for protection of the double circuit line. This paper proposes a solution for directional relaying of double circuit line combining four features. The technique is evaluated using data simulated with EMTDC/PSCAD for a double circuit line and the dynamic performance of the algorithm is also studied.","PeriodicalId":273164,"journal":{"name":"2011 International Conference on Energy, Automation and Signal","volume":"30 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"9","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 International Conference on Energy, Automation and Signal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICEAS.2011.6147079","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 9

Abstract

Protection of double circuit line is more complex than the single circuit. Problems associated with directional relaying for double circuit line during close-in fault, cross country fault, load change and with high resistance fault are addressed in this paper. Conventional directional relaying algorithm uses fault voltage and current phasors to derive the decisions and thus, finds its limitation during close-in fault, load change and cross country fault. In this work a directional relaying scheme using fuzzy logic system is proposed for protection of the double circuit line. This paper proposes a solution for directional relaying of double circuit line combining four features. The technique is evaluated using data simulated with EMTDC/PSCAD for a double circuit line and the dynamic performance of the algorithm is also studied.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
双回路方向继电器的解决方案
双回线路的保护要比单回线路复杂得多。本文讨论了双回线路定向继电在合闸故障、越野故障、负载变化和高阻故障时的继电问题。传统的定向继电算法采用故障电压和电流相量进行判定,在近距离故障、负荷变化和跨国故障时存在一定的局限性。本文提出了一种基于模糊逻辑系统的双向继电保护方案。本文提出了一种结合四种特点的双回线路定向继电保护方案。利用EMTDC/PSCAD双回线仿真数据对该算法进行了评价,并对算法的动态性能进行了研究。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
EQU-IITG: A multi-format formal equivalence checker Low power, dynamically reconfigurable, memoryless systolic array based architecture for Viterbi decoder Model reduction of linear interval systems using Kharitonov's polynomials An MIWO based approach of power system transient stability enhancement with STATCOM Energy efficiency invariance laws acting in the field of multiphase AC inverter drives
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1