Research on the AGC coordination control method including energy storage system based on area control error in the interconnected power grid

Peng Wang, Fang-ming Niu
{"title":"Research on the AGC coordination control method including energy storage system based on area control error in the interconnected power grid","authors":"Peng Wang, Fang-ming Niu","doi":"10.1109/IFEEC.2015.7361397","DOIUrl":null,"url":null,"abstract":"As the adjustment effect of automatic generation control (AGC) is not ideal in the interconnected power grid, and the independent control area doesn't have enough control resources, as well as the energy storage system has the characteristics of fast charging and discharging, this paper puts forward the AGC coordination control method including the energy storage system based on the area control error (ACE). This method would make the ACE in combination with energy storage system of charging and discharging very well, it enriches the AGC control strategies, makes up for the bad influence of the scarcity of regional control resource, and it has the advantages of artificially controlling cycle count and depth, and it is easy to modify the relevant parameters. By building algorithm case of two area interconnected power grid, simulation results under the environment of MATLAB/Simulink show that the energy storage system can improve the smooth degree of ACE, improve the quality of power grid frequency, and reduce the fluctuations of tie-line power.","PeriodicalId":268430,"journal":{"name":"2015 IEEE 2nd International Future Energy Electronics Conference (IFEEC)","volume":"104 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-12-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 IEEE 2nd International Future Energy Electronics Conference (IFEEC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IFEEC.2015.7361397","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

As the adjustment effect of automatic generation control (AGC) is not ideal in the interconnected power grid, and the independent control area doesn't have enough control resources, as well as the energy storage system has the characteristics of fast charging and discharging, this paper puts forward the AGC coordination control method including the energy storage system based on the area control error (ACE). This method would make the ACE in combination with energy storage system of charging and discharging very well, it enriches the AGC control strategies, makes up for the bad influence of the scarcity of regional control resource, and it has the advantages of artificially controlling cycle count and depth, and it is easy to modify the relevant parameters. By building algorithm case of two area interconnected power grid, simulation results under the environment of MATLAB/Simulink show that the energy storage system can improve the smooth degree of ACE, improve the quality of power grid frequency, and reduce the fluctuations of tie-line power.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于区域控制误差的互联电网储能系统AGC协调控制方法研究
针对互联电网中自动发电控制(AGC)调节效果不理想、独立控制区控制资源不足以及储能系统具有快速充放电的特点,提出了基于区域控制误差(ACE)的包括储能系统在内的AGC协调控制方法。该方法可以很好地使ACE与充放电储能系统相结合,丰富了AGC控制策略,弥补了区域控制资源稀缺性的不利影响,具有人为控制循环次数和深度的优点,且相关参数易于修改。通过建立两区互联电网的算法案例,在MATLAB/Simulink环境下进行仿真,结果表明,该储能系统可以提高ACE的平滑度,提高电网频率质量,降低联络线功率波动。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Study on a novel low-stress zero current switching technique in power converters An advanced fast charging strategy for lithium polymer batteries Diode-clamped three-level multi-module cascaded converter based power electronic traction transformer Impedance interference investigation of the paralleled DC/DC converters system used droop current sharing control Advanced-angle estimation of block commutation controlled IPMSM with DC-bus current measurement
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1