Localized Pool Boiling and Condensation Experiments over Functional CPU: Optimizing the Overall Thermal Resistance via Different Heat Transfer Scenarios

Chady al Sayed, Omidreza Ghaffari, Francis Grenier, W. Tong, M. Bolduc, J. Morissette, Simon Jasmin, J. Sylvestre
{"title":"Localized Pool Boiling and Condensation Experiments over Functional CPU: Optimizing the Overall Thermal Resistance via Different Heat Transfer Scenarios","authors":"Chady al Sayed, Omidreza Ghaffari, Francis Grenier, W. Tong, M. Bolduc, J. Morissette, Simon Jasmin, J. Sylvestre","doi":"10.1109/ITherm45881.2020.9190371","DOIUrl":null,"url":null,"abstract":"Pool boiling cooling systems are one of the most promising candidates to address the increase of electronics power consumption. This cooling technique still exhibits many challenges to be fully adopted, such as the high-reliability risk associated with the full immersion of electronic components in dielectric liquids and the film boiling phenomena. This paper reports an investigation of the effects of multiple boiling scenarios on the overall thermal resistance of a close two-phase cooling system, mounted directly over a functional microprocessor. Two dielectric fluids (Novec 649 and 7000 from the 3M Corporation) were tested over nickel and copper processor surfaces. A better overall thermal resistance was achieved when boiling the Novec 7000 on top of the copper exposed processor surface. Degassing the setup to remove non-condensable gases lowered the absolute pressure inside the system and reduced the overall thermal resistance. Moreover, partially immersing inward heat sink pins into the dielectric liquid was observed to also lower thermal resistance. The best boiling scenario was achieved while using Novec 7000 and combining all other improvements. A (0.38±0.01) °C/W minimum overall thermal resistance was calculated from junction to air at a (130±4) W power consumption and a (73±0.4) °C maximum junction temperature. This minimum overall thermal value was 30% lower than the one associated with the best boiling scenario using Novec 649.","PeriodicalId":193052,"journal":{"name":"2020 19th IEEE Intersociety Conference on Thermal and Thermomechanical Phenomena in Electronic Systems (ITherm)","volume":"15 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"9","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 19th IEEE Intersociety Conference on Thermal and Thermomechanical Phenomena in Electronic Systems (ITherm)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ITherm45881.2020.9190371","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 9

Abstract

Pool boiling cooling systems are one of the most promising candidates to address the increase of electronics power consumption. This cooling technique still exhibits many challenges to be fully adopted, such as the high-reliability risk associated with the full immersion of electronic components in dielectric liquids and the film boiling phenomena. This paper reports an investigation of the effects of multiple boiling scenarios on the overall thermal resistance of a close two-phase cooling system, mounted directly over a functional microprocessor. Two dielectric fluids (Novec 649 and 7000 from the 3M Corporation) were tested over nickel and copper processor surfaces. A better overall thermal resistance was achieved when boiling the Novec 7000 on top of the copper exposed processor surface. Degassing the setup to remove non-condensable gases lowered the absolute pressure inside the system and reduced the overall thermal resistance. Moreover, partially immersing inward heat sink pins into the dielectric liquid was observed to also lower thermal resistance. The best boiling scenario was achieved while using Novec 7000 and combining all other improvements. A (0.38±0.01) °C/W minimum overall thermal resistance was calculated from junction to air at a (130±4) W power consumption and a (73±0.4) °C maximum junction temperature. This minimum overall thermal value was 30% lower than the one associated with the best boiling scenario using Novec 649.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
功能性CPU的局部池沸腾和冷凝实验:通过不同的传热方案优化整体热阻
池沸腾冷却系统是解决电子产品功耗增加的最有希望的候选者之一。这种冷却技术仍面临许多挑战,如电子元件完全浸入介质液体和薄膜沸腾现象所带来的高可靠性风险。本文报告了多种沸腾场景对直接安装在功能微处理器上的紧密两相冷却系统的总热阻的影响的研究。两种介电流体(3M公司的Novec 649和7000)在镍和铜处理器表面上进行了测试。当Novec 7000在铜暴露的处理器表面上沸腾时,获得了更好的整体热阻。对装置进行脱气以去除不可冷凝气体,降低了系统内的绝对压力,降低了总体热阻。此外,将散热器引脚部分浸入介质液体中也可以降低热阻。最佳沸腾场景是在使用Novec 7000并结合所有其他改进时实现的。在(130±4)W功耗和(73±0.4)C最高结温下,从结到空气的最小总热阻为(0.38±0.01)°C/W。这一最小总热值比使用Novec 649的最佳沸腾情况下的最低热值低30%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Thermal Sensor Placement based on Meta-Model Enhancing Observability and Controllability A Cascaded Multi-Core Vapor Chamber for Intra-Lid Heat Spreading in Heterogeneous Packages Corrosion in Liquid Cooling Systems with Water-Based Coolant – Part 2: Corrosion Reliability Testing and Failure Model A Reduced-order Model for Analyzing Heat Transfer in a Thermal Energy Storage Module Systematic Approach in Intel SoC (System on Chip) Thermal Solution Design using CFD (Computational Fluid Dynamics) Simulation
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1