2-D FEM simulation of an electromagnetic flowmeter

M.A. Rodriguez, D. Morinigo, J. Fernandez, R. Cuesta, J. Maroto
{"title":"2-D FEM simulation of an electromagnetic flowmeter","authors":"M.A. Rodriguez, D. Morinigo, J. Fernandez, R. Cuesta, J. Maroto","doi":"10.1109/OPTIM.2008.4602345","DOIUrl":null,"url":null,"abstract":"A computational investigation was carried out in a contactless electromagnetic induction flowmeter to measure the velocity of molten aluminum flowing though a ceramic duct. This paper includes the simulation and the experimental validation using as a reference the electromagnetic induction flowmeter and the experimental test. The results make it possible to demonstrate the reliability of the simulation of the electromagnetic induction flowmeter, using ANSYS. This work provides the process for the simulation of an contacless electromagnetic induction flowmeter to measure the flowrate of molten aluminum in the EPGS (Electromagnetic Pump Green Sand) casting process.","PeriodicalId":244464,"journal":{"name":"2008 11th International Conference on Optimization of Electrical and Electronic Equipment","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2008-05-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2008 11th International Conference on Optimization of Electrical and Electronic Equipment","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/OPTIM.2008.4602345","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

A computational investigation was carried out in a contactless electromagnetic induction flowmeter to measure the velocity of molten aluminum flowing though a ceramic duct. This paper includes the simulation and the experimental validation using as a reference the electromagnetic induction flowmeter and the experimental test. The results make it possible to demonstrate the reliability of the simulation of the electromagnetic induction flowmeter, using ANSYS. This work provides the process for the simulation of an contacless electromagnetic induction flowmeter to measure the flowrate of molten aluminum in the EPGS (Electromagnetic Pump Green Sand) casting process.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
电磁流量计的二维有限元模拟
采用非接触式电磁感应流量计对铝液在陶瓷管道中的流动速度进行了计算研究。本文以电磁感应流量计为参考,进行了仿真和实验验证,并进行了实验测试。研究结果证明了利用ANSYS对电磁感应流量计进行仿真的可靠性。本工作为非接触式电磁感应流量计在EPGS(电磁泵绿砂)铸造过程中测量铝液流量提供了仿真过程。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Stand-alone power system with synchronous and asynchronous generators Analysis of permanent magnet claw-pole synchronous machine Control methods on unstable periodic orbits of a chaotic dynamical system — control chaos in buck converter Modular test bench for a hybrid electric vehicle with multiples energy sources Improvement of voltage stability and reduce power system losses by optimal GA-based allocation of multi-type FACTS devices
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1