Evaluation of RIP sensor calibration stability for daily estimation of lung volume

Raul I. Ramos-Garcia, M. Imtiaz, E. Sazonov, Stephen T. Tiffany
{"title":"Evaluation of RIP sensor calibration stability for daily estimation of lung volume","authors":"Raul I. Ramos-Garcia, M. Imtiaz, E. Sazonov, Stephen T. Tiffany","doi":"10.1109/ICSENST.2017.8304419","DOIUrl":null,"url":null,"abstract":"This work supports the development of a non-invasive wearable system for the tracking of cigarette smoking in the natural environment. Accurate estimation of lung volume, as well as preservation of calibration over the period of wear, are required for such a system. In this paper, the preservation of calibration of a Respiratory Inductive Plethysmograph (RIP) in a 24-hour period was evaluated. Attachment options, such as an RIP belt held in place by tension (belt), RIP belt held in place by adhesive (belt+adhesive), and RIP belt sewn into a T-shirt (belt+shirt) were studied and compared using data collected from three subjects performing usual daily activities. An 800 ml bag was used as the gold standard for evaluation. The average volume obtained for the belt, belt+adhesive, and belt+shirt options were 0.89+0.28 L, 1.02+0.27 L, and 0.79+0.05 L, respectively. Additionally, comparing these against a reference volume of 800 ml, the average RMSE was 0.24+0.05 L, 0.24+0.23 L, and 0.03+0.03 L, respectively. Results show that the RIP belt sewn into a T-shirt provides a better preservation of the calibration throughout the 24-hour period.","PeriodicalId":289209,"journal":{"name":"2017 Eleventh International Conference on Sensing Technology (ICST)","volume":"105 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"10","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 Eleventh International Conference on Sensing Technology (ICST)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICSENST.2017.8304419","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 10

Abstract

This work supports the development of a non-invasive wearable system for the tracking of cigarette smoking in the natural environment. Accurate estimation of lung volume, as well as preservation of calibration over the period of wear, are required for such a system. In this paper, the preservation of calibration of a Respiratory Inductive Plethysmograph (RIP) in a 24-hour period was evaluated. Attachment options, such as an RIP belt held in place by tension (belt), RIP belt held in place by adhesive (belt+adhesive), and RIP belt sewn into a T-shirt (belt+shirt) were studied and compared using data collected from three subjects performing usual daily activities. An 800 ml bag was used as the gold standard for evaluation. The average volume obtained for the belt, belt+adhesive, and belt+shirt options were 0.89+0.28 L, 1.02+0.27 L, and 0.79+0.05 L, respectively. Additionally, comparing these against a reference volume of 800 ml, the average RMSE was 0.24+0.05 L, 0.24+0.23 L, and 0.03+0.03 L, respectively. Results show that the RIP belt sewn into a T-shirt provides a better preservation of the calibration throughout the 24-hour period.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
日常肺容量估计的RIP传感器校准稳定性评价
这项工作支持了一种非侵入式可穿戴系统的开发,用于跟踪自然环境中的吸烟情况。这种系统需要准确估计肺容量,以及在磨损期间保存校准。在本文中,评估了在24小时内保存呼吸感应容积描记仪(RIP)的校准。研究和比较了三个日常活动的受试者的数据,包括通过张力固定的RIP皮带(皮带)、通过粘合剂固定的RIP皮带(皮带+粘合剂)和缝在t恤上的RIP皮带(皮带+衬衫)。以800 ml袋作为金标准进行评价。皮带、皮带+胶粘剂和皮带+衬衫的平均体积分别为0.89+0.28 L、1.02+0.27 L和0.79+0.05 L。此外,将这些与800 ml的参考体积进行比较,平均RMSE分别为0.24+0.05 L, 0.24+0.23 L和0.03+0.03 L。结果表明,缝制在t恤上的RIP带在整个24小时内提供了更好的校准保存。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Self adjustable daylight sensor for lighting systems Wheatstone bridge approach to the inspection of composite materials Demonstrator for online measurement of combustion gases NO, NO2 and SO2: A compact sensor system for highly resolved detection of hazardous emission gases Regeneratable surface acoustic wave (SAW) immunosensor for monitoring of physiological information Integration of an automatic agricultural and livestock production management system and an agriculture and food traceability system based on the Internet of Things technology
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1