{"title":"Mobile laser photoacoustic spectrometer for multicomponent trace-gas monitoring based on CO/sub 2/- and quantum-cascade lasers as pump sources","authors":"M. Nagele, D. Hofstetter, J. Faist, M. Sigrist","doi":"10.1109/CLEOE.2000.909779","DOIUrl":null,"url":null,"abstract":"Summary form only given. The development and application of a mobile laser-photoacoustic spectrometer for in-situ multicomponent monitoring of trace gases in different environments is reported. Sub-ppbV (<10/sup -9/ per volume)-concentrations can be measured with a novel resonant multipass photoacoustic cell. For ethene (C/sub 2/H/sub 4/) buffered in synthetic air a minimum detection limit of 70 pptV (70/spl times/10/sup -12/ per volume) is achieved with a line-tunable CO/sub 2/-laser as pump source corresponding to a minimum measurable absorption coefficient /spl alpha//sub min/=2/spl times/10/sup -9/ cm/sup -1/ for a signal-to-noise ratio of 3. The multicomponent capability of the system is demonstrated with continuous sequential measurements of gases such as ethene, methanol, and ethanol of air from a fruit storage chamber.","PeriodicalId":250878,"journal":{"name":"Conference Digest. 2000 Conference on Lasers and Electro-Optics Europe (Cat. No.00TH8505)","volume":"46 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2000-09-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Conference Digest. 2000 Conference on Lasers and Electro-Optics Europe (Cat. No.00TH8505)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CLEOE.2000.909779","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3
Abstract
Summary form only given. The development and application of a mobile laser-photoacoustic spectrometer for in-situ multicomponent monitoring of trace gases in different environments is reported. Sub-ppbV (<10/sup -9/ per volume)-concentrations can be measured with a novel resonant multipass photoacoustic cell. For ethene (C/sub 2/H/sub 4/) buffered in synthetic air a minimum detection limit of 70 pptV (70/spl times/10/sup -12/ per volume) is achieved with a line-tunable CO/sub 2/-laser as pump source corresponding to a minimum measurable absorption coefficient /spl alpha//sub min/=2/spl times/10/sup -9/ cm/sup -1/ for a signal-to-noise ratio of 3. The multicomponent capability of the system is demonstrated with continuous sequential measurements of gases such as ethene, methanol, and ethanol of air from a fruit storage chamber.