A HF transformer design methodology for high efficiency isolated ZVS DC/DC converters

J. Schmidt, G. Azevedo, M. Cavalcanti, J. R. Pinheiro
{"title":"A HF transformer design methodology for high efficiency isolated ZVS DC/DC converters","authors":"J. Schmidt, G. Azevedo, M. Cavalcanti, J. R. Pinheiro","doi":"10.1109/COBEP.2017.8257314","DOIUrl":null,"url":null,"abstract":"Proper design of High-Frequency (HF) and Low-Frequency (LF) transformers parameters is one of the key elements for a high-performance isolated converters design. In practice, transformer designers have employed several techniques for achieve suitable designs, assuming rules of thumbs based on their expertise. In this paper, a design methodology for HF transformers based on product areas (Ap) that uses iterative processes in combination with rules of thumb for different specific variables, is presented and discussed. The most suitable design results for 100 kHz are implemented and validated to 1.5kW ZVS DC/DC Full-Bridge converter. Results shown the temperature rise achieve the estimated value of 13.9 °C, and a HF transformer efficiency of 99.64%, in which it brings converter efficiency close to 97.50% at rated power.","PeriodicalId":375493,"journal":{"name":"2017 Brazilian Power Electronics Conference (COBEP)","volume":"33 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 Brazilian Power Electronics Conference (COBEP)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/COBEP.2017.8257314","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Proper design of High-Frequency (HF) and Low-Frequency (LF) transformers parameters is one of the key elements for a high-performance isolated converters design. In practice, transformer designers have employed several techniques for achieve suitable designs, assuming rules of thumbs based on their expertise. In this paper, a design methodology for HF transformers based on product areas (Ap) that uses iterative processes in combination with rules of thumb for different specific variables, is presented and discussed. The most suitable design results for 100 kHz are implemented and validated to 1.5kW ZVS DC/DC Full-Bridge converter. Results shown the temperature rise achieve the estimated value of 13.9 °C, and a HF transformer efficiency of 99.64%, in which it brings converter efficiency close to 97.50% at rated power.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
高效隔离ZVS DC/DC变换器的高频变压器设计方法
高频和低频变压器参数的合理设计是高性能隔离型变换器设计的关键因素之一。实际上,变压器设计人员已经采用了几种技术来实现合适的设计,假设基于他们的专业知识的经验规则。本文提出并讨论了一种基于产品区域(Ap)的高频变压器设计方法,该方法使用迭代过程结合不同特定变量的经验法则。实现了最适合100 kHz的设计结果,并验证了1.5kW ZVS DC/DC全桥变换器。结果表明,温升达到了估计值13.9℃,高频变压器效率达到99.64%,其中变换器在额定功率下的效率接近97.50%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Inverter-based motor drive systems: An overview from the electromagnetic compatibility perspective Impact of PV systems on microgrids under different levels of penetration and operational scenarios A case study of adaptive microgrid protection during transitions and operations An alternative analysis of AC-AC PWM converter voltage stabilizer Performance comparison of IGBTS and SIC-MOSFET applied in photovoltaic inverters during reactive power injection
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1