High Sensitive Gas Leakage Detector With Automatic Dialer System

Dr. Shaik Mahammad Rasool et al.
{"title":"High Sensitive Gas Leakage Detector With Automatic Dialer System","authors":"Dr. Shaik Mahammad Rasool et al.","doi":"10.52783/cienceng.v11i1.96","DOIUrl":null,"url":null,"abstract":"Now-a-days due to the increase in number of automobiles there has been an extensive use of automobiles in day-to-day life. Usage of vehicles reduces the journey time but at the same time it increases the harmful gases like Butane, propane, CO, LPG etc levels which has a severe effect on human health. For example Carbon monoxide is a toxic gas, but, being colorless, odorless, tasteless, and initially non-irritating, it is very difficult for people to detect. Carbon monoxide is a product of incomplete combustion of organic matter due to insufficient oxygen supply to enable complete oxidation to carbon dioxide (CO2). It is often produced in domestic or industrial settings by older motor vehicles and other gasoline-powered tools, heaters, and cooking equipment. Symptoms of mild acute poisoning include light headedness, confusion, headaches, vertigo, and flu-like effects; larger exposures can lead to significant toxicity of the central nervous system and heart, and even deathThis project eliminates the above problems. The proposed projects detects the level of Carbon Monoxide and whenever it reaches threshold (harmful) limit the engine of the vehicle will be turn off and the buzzer will be switched on. It also gives a visual display on LED. Thus, saving the environment and human lives from the dangerous, life threatening effects of several hazardous gases like butane, propane, CO and LPG etc. \nThis project uses regulated 5V, 500mA power supply. 7805 three terminal voltage regulator is used for voltage regulation. Bridge type full wave rectifier is used to rectify the ac output of secondary of 230/12V step down transformer","PeriodicalId":214525,"journal":{"name":"Proceeding International Conference on Science and Engineering","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-02-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceeding International Conference on Science and Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.52783/cienceng.v11i1.96","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Now-a-days due to the increase in number of automobiles there has been an extensive use of automobiles in day-to-day life. Usage of vehicles reduces the journey time but at the same time it increases the harmful gases like Butane, propane, CO, LPG etc levels which has a severe effect on human health. For example Carbon monoxide is a toxic gas, but, being colorless, odorless, tasteless, and initially non-irritating, it is very difficult for people to detect. Carbon monoxide is a product of incomplete combustion of organic matter due to insufficient oxygen supply to enable complete oxidation to carbon dioxide (CO2). It is often produced in domestic or industrial settings by older motor vehicles and other gasoline-powered tools, heaters, and cooking equipment. Symptoms of mild acute poisoning include light headedness, confusion, headaches, vertigo, and flu-like effects; larger exposures can lead to significant toxicity of the central nervous system and heart, and even deathThis project eliminates the above problems. The proposed projects detects the level of Carbon Monoxide and whenever it reaches threshold (harmful) limit the engine of the vehicle will be turn off and the buzzer will be switched on. It also gives a visual display on LED. Thus, saving the environment and human lives from the dangerous, life threatening effects of several hazardous gases like butane, propane, CO and LPG etc. This project uses regulated 5V, 500mA power supply. 7805 three terminal voltage regulator is used for voltage regulation. Bridge type full wave rectifier is used to rectify the ac output of secondary of 230/12V step down transformer
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
具有自动拨号系统的高灵敏度气体泄漏检测器
如今,由于汽车数量的增加,人们在日常生活中广泛使用汽车。车辆的使用减少了旅行时间,但同时也增加了丁烷、丙烷、一氧化碳、液化石油气等有害气体的含量,对人体健康造成严重影响。例如,一氧化碳是一种有毒气体,但是,由于它无色、无嗅、无味,而且最初没有刺激性,所以人们很难检测到它。一氧化碳是有机物不完全燃烧的产物,因为氧气供应不足,无法完全氧化成二氧化碳。它通常在家庭或工业环境中由旧的机动车辆和其他汽油动力工具,加热器和烹饪设备产生。轻度急性中毒的症状包括轻微头痛、精神错乱、头痛、眩晕和流感样症状;更大的暴露会导致中枢神经系统和心脏的显著毒性,甚至死亡。拟议的项目检测一氧化碳水平,当它达到阈值(有害)限制时,车辆的发动机将被关闭,蜂鸣器将被打开。它还可以在LED上进行视觉显示。因此,从丁烷、丙烷、一氧化碳和液化石油气等几种有害气体的危险、威胁生命的影响中拯救环境和人类生命。本项目采用稳压5V, 500mA电源。7805三端稳压器用于电压调节。桥式全波整流器用于整流230/12V降压变压器二次交流输出
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Impact of Cloud-Based HR Systems on Business Performance Metrics Use of Gesture Recognition for Differently Abled Persons Study on Lead Iodide-Polyvinyl Alcohol Polymer Composites as an X-ray Shielding Material A Novel Heterogenous Dominant Sequence Clustering for Task Scheduling and Optimal Load Balancing Using JSO in Cloud Motivational Theories and Their Relevance in Military Motivation
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1