Respiratory Frequency Estimation Method Based on Periodic Features Using UWB Radar

Boning Guo, Zhaocheng Yang, Yige Cheng, Jian-hua Zhou
{"title":"Respiratory Frequency Estimation Method Based on Periodic Features Using UWB Radar","authors":"Boning Guo, Zhaocheng Yang, Yige Cheng, Jian-hua Zhou","doi":"10.1109/ICEICT51264.2020.9334351","DOIUrl":null,"url":null,"abstract":"In this paper, we propose an algorithm for adaptively extracting respiratory waveform and estimating respiratory rate in different target states based on ultrawideband (UWB) radar. At present, the respiratory rate can be estimated in most algorithms only when the target is stationary. The proposed algorithm performs target state determination through fast time and slow time matrices respectively. The two detection procedures are cascaded to determine the target's state (namely, target absence, motion and breathing) and the human breathing area. In the following, the proposed algorithm adaptively extracts the respiratory waveform through the features of respiratory periodicity, which can overcome the shortcoming caused by the maximum energy range bin approach in the case of low signal-noise ratio (SNR). Finally, the respiratory frequency is estimated by the frequency time phase regression (FTPR) method. The experimental results show that the mean square error (MSE) between the estimated respiratory rate and the result of the multi-channel physiological recorder is 0.4664 breathvmin,","PeriodicalId":124337,"journal":{"name":"2020 IEEE 3rd International Conference on Electronic Information and Communication Technology (ICEICT)","volume":"40 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-11-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 IEEE 3rd International Conference on Electronic Information and Communication Technology (ICEICT)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICEICT51264.2020.9334351","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

In this paper, we propose an algorithm for adaptively extracting respiratory waveform and estimating respiratory rate in different target states based on ultrawideband (UWB) radar. At present, the respiratory rate can be estimated in most algorithms only when the target is stationary. The proposed algorithm performs target state determination through fast time and slow time matrices respectively. The two detection procedures are cascaded to determine the target's state (namely, target absence, motion and breathing) and the human breathing area. In the following, the proposed algorithm adaptively extracts the respiratory waveform through the features of respiratory periodicity, which can overcome the shortcoming caused by the maximum energy range bin approach in the case of low signal-noise ratio (SNR). Finally, the respiratory frequency is estimated by the frequency time phase regression (FTPR) method. The experimental results show that the mean square error (MSE) between the estimated respiratory rate and the result of the multi-channel physiological recorder is 0.4664 breathvmin,
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于周期特征的超宽带雷达呼吸频率估计方法
本文提出了一种基于超宽带雷达的呼吸波形自适应提取和呼吸频率估计算法。目前,大多数算法只能在目标静止时估计呼吸速率。该算法分别通过快时间矩阵和慢时间矩阵确定目标状态。两个检测过程级联,确定目标的状态(即目标缺席、运动和呼吸)和人体呼吸区域。本文提出的算法利用呼吸周期的特征自适应提取呼吸波形,克服了低信噪比下最大能量范围bin法的缺点。最后,采用频率时相回归(FTPR)方法估计呼吸频率。实验结果表明,呼吸频率估计值与多通道生理记录仪测量值的均方误差(MSE)为0.4664 breathvmin;
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Inter-Satellite Broadcast Topology Planning Method for Walker Constellation Using TDMA Link Apple Leaf Disease Identification and Classification using ResNet Models CRC-Aided Belief Propagation with Permutated Graphs Decoding of Polar Codes High-efficiency Receiver-Transmitter Metasurfaces with Independent Control of Polarization, Amplitude and Phase Microwave sensor based on complementary circular spiral resonator for non-destructive testing of cracks in dielectric plate
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1