M. Donnelly, D. Trudnowski, James Colwell, J. Pierre, L. Dosiek
{"title":"RMS-energy filter design for real-time oscillation detection","authors":"M. Donnelly, D. Trudnowski, James Colwell, J. Pierre, L. Dosiek","doi":"10.1109/PESGM.2015.7286192","DOIUrl":null,"url":null,"abstract":"Real-time monitoring of power-system oscillations is a concern in the operation and control of synchronous power systems. A simple and powerful approach is to use an RMS energy filter. As defined in this paper, an RMS energy filter estimates the total RMS energy of a signal in a defined frequency band. This approach has been implemented in the operation control center at the Bonneville Power Administration for the past year, and it is being implemented in a DC modulation damping control monitoring system. This paper describes RMS energy filter design requirements, approaches, and alternatives. Simulation examples demonstrate the performance.","PeriodicalId":423639,"journal":{"name":"2015 IEEE Power & Energy Society General Meeting","volume":"20 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-07-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"30","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 IEEE Power & Energy Society General Meeting","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PESGM.2015.7286192","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 30
Abstract
Real-time monitoring of power-system oscillations is a concern in the operation and control of synchronous power systems. A simple and powerful approach is to use an RMS energy filter. As defined in this paper, an RMS energy filter estimates the total RMS energy of a signal in a defined frequency band. This approach has been implemented in the operation control center at the Bonneville Power Administration for the past year, and it is being implemented in a DC modulation damping control monitoring system. This paper describes RMS energy filter design requirements, approaches, and alternatives. Simulation examples demonstrate the performance.