Retention Load and Volume Loss of Telescopic PEEK Crowns with Different Tapers Angles and thickness: in vitro study.

R. Hassan, Sherin Donia
{"title":"Retention Load and Volume Loss of Telescopic PEEK Crowns with Different Tapers Angles and thickness: in vitro study.","authors":"R. Hassan, Sherin Donia","doi":"10.21608/ajdsm.2022.162091.1366","DOIUrl":null,"url":null,"abstract":"Objective: The aim of this study was to investigate the Retention force and Volume Loss of CAD/CAM-fabricated polyetheretherketone (PEEK) telescopic crowns which with different Tapers and Thicknesses. Material and methods: Peek primary crowns (N = 5) were CAD/CAM milled and provided with secondary crowns CAD/CAM-fabricated PEEK secondary crowns (group N = 5). The universal testing machine was used to determine the retentive force and volume loss at values at baseline and after 3, 6, 9, and 12 months. Data were analyzed by using Statistical Package for Social Sciences P value <0.05(*) was considered a significant difference & P-value <0.001(**) was considered a highly significant difference. Results: Maximum Retentive Load results were analyzed by using mean and standard deviation. repeated measure ANOVA test is used to compare duration in each group in which there is a highly significant difference between durations, also One Way ANOVA test is used to compare groups in each period, while there is no significant difference between groups in each duration. PEEK; secondary crowns exhibit stable retentive force values over 12 months of use showing no signs of deterioration while the retentive force values of electroformed secondary crowns increase over time. Conclusions: Clinical relevance PEEK might be a suitable alternative to proven metallic materials for the fabrication of secondary crowns.","PeriodicalId":117944,"journal":{"name":"Al-Azhar Journal of Dental Science","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2022-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Al-Azhar Journal of Dental Science","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.21608/ajdsm.2022.162091.1366","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Objective: The aim of this study was to investigate the Retention force and Volume Loss of CAD/CAM-fabricated polyetheretherketone (PEEK) telescopic crowns which with different Tapers and Thicknesses. Material and methods: Peek primary crowns (N = 5) were CAD/CAM milled and provided with secondary crowns CAD/CAM-fabricated PEEK secondary crowns (group N = 5). The universal testing machine was used to determine the retentive force and volume loss at values at baseline and after 3, 6, 9, and 12 months. Data were analyzed by using Statistical Package for Social Sciences P value <0.05(*) was considered a significant difference & P-value <0.001(**) was considered a highly significant difference. Results: Maximum Retentive Load results were analyzed by using mean and standard deviation. repeated measure ANOVA test is used to compare duration in each group in which there is a highly significant difference between durations, also One Way ANOVA test is used to compare groups in each period, while there is no significant difference between groups in each duration. PEEK; secondary crowns exhibit stable retentive force values over 12 months of use showing no signs of deterioration while the retentive force values of electroformed secondary crowns increase over time. Conclusions: Clinical relevance PEEK might be a suitable alternative to proven metallic materials for the fabrication of secondary crowns.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
不同锥度、角度和厚度的PEEK冠的固位负荷和体积损失的体外研究。
目的:研究CAD/ cam制备的不同锥度和厚度的聚醚醚酮(PEEK)套筒冠的固位力和体积损失。材料和方法:将Peek初级冠(N = 5)进行CAD/CAM铣削,并提供CAD/CAM制造的Peek二级冠(N = 5)。使用通用试验机测定基线值和3、6、9、12个月后的固位力和体积损失。数据采用Statistical Package for Social Sciences进行分析,P值<0.05(*)为显著差异,P值<0.001(**)为极显著差异。结果:采用均值和标准差对最大保留负荷结果进行分析。各组间持续时间比较采用重复测量方差分析,各组间持续时间差异极显著;各组间各持续时间比较采用单因素方差分析,各组间各持续时间差异不显著。偷看;电铸牙冠的固位力随时间的增加而增加,但在使用12个月后,牙冠的固位力稳定,无退化迹象。结论:具有临床意义的聚醚醚酮可能是一种合适的替代金属材料制作第二冠的方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Evaluation of clinical effect of titanium-prepared platelet-rich fibrin and platelet- rich fibrin in treatment of gingival recession Fracture resistance of CAD CAM endocrowns bonded to teeth with different number of remaining walls :An In-Vitro Study. Evaluation of the effect of vitamin D on the salivary and serum levels of interleukin-8 in patients with periodontitis stage I and II grade A. The Effectiveness Of Topical Avocado In The Treatment Of Minor Recurrent Aphthous Ulceration: A Randomized Controlled Clinical Trial Modulus of Elasticity of Different Resin Denture Base Materials: A Comparative Study
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1