Effect of time and electrical potential gradient on the buffer capacity of soils, as measured using an electrokinetic method

M. Vázquez, D. Vasco, F. Hernández-Luis
{"title":"Effect of time and electrical potential gradient on the buffer capacity of soils, as measured using an electrokinetic method","authors":"M. Vázquez, D. Vasco, F. Hernández-Luis","doi":"10.2462/09670513.895","DOIUrl":null,"url":null,"abstract":"The buffer capacity of soils is a property of interest in the field of environmental remediation, and is related to chemical properties such as the nature of soil humic material and the variable charged surfaces of clays and hydrated oxides. An electrokinetic technique has been proposed as a method for the determination of the buffer capacity of soils, making use of the electrolytic reactions of water that arise after the application of an electrical field. Such reactions produce hydronium and hydroxyl ions, which are continually entering the soil. A study was made of the effect of the duration of the electrokinetic process (24, 48 and 72 h), as well as of the electrical potential gradient applied to the soil (1.2 and 1.8 V/cm), in the determination of the buffer capacity of a soil of volcanic origin. It was observed that time had a significant effect on the value obtained for the buffer capacity in a basic medium (fβ–), and that both variables had a significant effect on that obtained in an acid medium (fβ+). Moreover, the buffer capacity of two soils of volcanic origin obtained using the electrokinetic technique was compared with that obtained using the traditional volumetric method. The results obtained using both techniques showed good agreement.","PeriodicalId":336428,"journal":{"name":"Land Contamination & Reclamation","volume":"26 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2008-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Land Contamination & Reclamation","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2462/09670513.895","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

The buffer capacity of soils is a property of interest in the field of environmental remediation, and is related to chemical properties such as the nature of soil humic material and the variable charged surfaces of clays and hydrated oxides. An electrokinetic technique has been proposed as a method for the determination of the buffer capacity of soils, making use of the electrolytic reactions of water that arise after the application of an electrical field. Such reactions produce hydronium and hydroxyl ions, which are continually entering the soil. A study was made of the effect of the duration of the electrokinetic process (24, 48 and 72 h), as well as of the electrical potential gradient applied to the soil (1.2 and 1.8 V/cm), in the determination of the buffer capacity of a soil of volcanic origin. It was observed that time had a significant effect on the value obtained for the buffer capacity in a basic medium (fβ–), and that both variables had a significant effect on that obtained in an acid medium (fβ+). Moreover, the buffer capacity of two soils of volcanic origin obtained using the electrokinetic technique was compared with that obtained using the traditional volumetric method. The results obtained using both techniques showed good agreement.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
时间和电位梯度对土壤缓冲能力的影响,用电动力学方法测定
土壤的缓冲能力是环境修复领域的一个重要特性,它与土壤腐殖质的性质、粘土和水合氧化物的可变带电表面等化学特性有关。利用电场作用后产生的水的电解反应,提出了一种电动力学技术,作为测定土壤缓冲容量的方法。这种反应产生水合氢离子和羟基离子,它们不断进入土壤。研究了电动过程持续时间(24、48和72小时)的影响,以及施加在土壤上的电位梯度(1.2和1.8 V/cm),以确定火山土壤的缓冲能力。观察到,时间对在碱性介质(fβ -)中获得的缓冲容量值有显著影响,这两个变量对在酸性介质(fβ+)中获得的缓冲容量值有显著影响。此外,还比较了两种火山成因土壤的缓冲容量,并与传统的体积法进行了比较。两种方法的结果一致。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Surfactant-enhanced soil washing for the remediation of sites contaminated with pesticides. Cheby or not Cheby? Is that the question? Alternative integration procedures in combining multiple exposure routes for the derivation of generic assessment criteria with the CLEA model. Contaminated land risk assessment: variability in site assessment and decision making in the UK. New technologies for long-term protection of drinking-water resources from landfill emissions - investigation, containment and targeted material conversion.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1