Statistical Parameters of the Measured Voltage in the Network

M. Guzan, Ádám Fehér, T. Vince
{"title":"Statistical Parameters of the Measured Voltage in the Network","authors":"M. Guzan, Ádám Fehér, T. Vince","doi":"10.1109/EDPE.2019.8883890","DOIUrl":null,"url":null,"abstract":"In the article we present a graphical representation of selected statistical parameters long-time measurement of the voltage in the network. The parameters are calculated from samples of 900 measured values (15-minute measurement interval - one measured value per second), measured by UT 803 multimeter. Changes in statistical parameters will allow to detect the dynamics of connecting/disconnecting electrical appliances, long-term too high or too low voltage, or short-time power failure. The reason for some major parameter changes is revealed by a graphical representation of the time courses of the respective measurement section at that day and hour.","PeriodicalId":353978,"journal":{"name":"2019 International Conference on Electrical Drives & Power Electronics (EDPE)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 International Conference on Electrical Drives & Power Electronics (EDPE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EDPE.2019.8883890","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

In the article we present a graphical representation of selected statistical parameters long-time measurement of the voltage in the network. The parameters are calculated from samples of 900 measured values (15-minute measurement interval - one measured value per second), measured by UT 803 multimeter. Changes in statistical parameters will allow to detect the dynamics of connecting/disconnecting electrical appliances, long-term too high or too low voltage, or short-time power failure. The reason for some major parameter changes is revealed by a graphical representation of the time courses of the respective measurement section at that day and hour.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
网络中测量电压的统计参数
在本文中,我们提出了一个图形表示的选择统计参数长期测量的电压在网络中。参数由UT 803万用表测量的900个测量值(15分钟测量间隔-每秒一个测量值)的样本计算得出。统计参数的变化将允许检测连接/断开电器的动态,长期过高或过低的电压,或短时间的电源故障。一些主要参数变化的原因由该日和该时各测量段的时间轨迹的图形表示来揭示。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Automated Preliminary Design of Induction Machines Aided by Artificial Neural Networks Investigation of Induction Machine with Rotor-Bar Faults Comparison of Thermal Properties of the Magnetic Components of Interleaved DC/DC Converters Application of Hybrid Neural Network to Detection of Induction Motor Electrical Faults Design and Functional Demonstration of a 100 A Battery Testing Unit with Minimal Power Supply Load
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1