S. Boorman, K. Lascola, M. Mora-Pereira, S. Ceriotti, L. Boone
{"title":"Internal Fixation of a Complicated Mandibular Fracture in a Filly Using a String-of-Pearls Locking Plate Assisted by a 3D Printed Model","authors":"S. Boorman, K. Lascola, M. Mora-Pereira, S. Ceriotti, L. Boone","doi":"10.1055/s-0040-1716351","DOIUrl":null,"url":null,"abstract":"Abstract Objective The aim of this study was to describe the successful surgical treatment of a complicated mandibular fracture with a 3.5 mm string-of-pearls (SOP) locking plate in a 5-month-old Appaloosa filly presenting with neurological signs. Study Design This is a case report. Results The neurological signs were due to severe head trauma and stabilized with medical treatment. Financial concerns initially prevented advanced imaging; radiographs identified a mandibular symphysis fracture, a fracture of the left vertical ramus that originated at the junction between the horizontal and vertical ramus and extended toward the coronoid process and rostral maxillary fractures. Following intra-dental wiring of the symphysis fracture, a lateral malocclusion developed. Computed tomography additionally identified fractures of the right wing of the basisphenoid bone, right zygomatic arch, left paracondylar process and the lateral body of the mandible. The vertical ramus fracture was repaired utilizing a 20-hole 3.5 mm SOP plate contoured to the ventral aspect of the angle of the mandible. A scaled (1:4) three-dimensional printed model aided pre- and intra-operative surgical planning. The filly was comfortable and eating well at the 4-week recheck. Radiographs showed good callus formation at the maxilla, healing of the mandibular symphysis and ramus. Just prior to the 10-week recheck, the filly suffered severe enterocolitis and was euthanatized. Conclusion The locking function of the SOP plate provided adequate stability for the fracture to heal without the expense of locking screws. The three-dimensional printed model aided in navigation of the complex fracture without the availability of fluoroscopy.","PeriodicalId":443672,"journal":{"name":"VCOT Open","volume":"40 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"VCOT Open","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1055/s-0040-1716351","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1
Abstract
Abstract Objective The aim of this study was to describe the successful surgical treatment of a complicated mandibular fracture with a 3.5 mm string-of-pearls (SOP) locking plate in a 5-month-old Appaloosa filly presenting with neurological signs. Study Design This is a case report. Results The neurological signs were due to severe head trauma and stabilized with medical treatment. Financial concerns initially prevented advanced imaging; radiographs identified a mandibular symphysis fracture, a fracture of the left vertical ramus that originated at the junction between the horizontal and vertical ramus and extended toward the coronoid process and rostral maxillary fractures. Following intra-dental wiring of the symphysis fracture, a lateral malocclusion developed. Computed tomography additionally identified fractures of the right wing of the basisphenoid bone, right zygomatic arch, left paracondylar process and the lateral body of the mandible. The vertical ramus fracture was repaired utilizing a 20-hole 3.5 mm SOP plate contoured to the ventral aspect of the angle of the mandible. A scaled (1:4) three-dimensional printed model aided pre- and intra-operative surgical planning. The filly was comfortable and eating well at the 4-week recheck. Radiographs showed good callus formation at the maxilla, healing of the mandibular symphysis and ramus. Just prior to the 10-week recheck, the filly suffered severe enterocolitis and was euthanatized. Conclusion The locking function of the SOP plate provided adequate stability for the fracture to heal without the expense of locking screws. The three-dimensional printed model aided in navigation of the complex fracture without the availability of fluoroscopy.
摘要目的描述3.5 mm珍珠串(SOP)锁定钢板成功治疗5月龄阿帕卢萨母马出现神经系统症状的复杂下颌骨骨折。研究设计这是一份病例报告。结果患者的神经症状多为严重颅脑外伤所致,经药物治疗后病情稳定。最初,资金问题阻碍了高级成像;x线片确认为下颌骨联合骨折,左侧垂直支骨折,起源于水平支和垂直支之间的连接处,并向冠突和上颌吻侧骨折延伸。在牙内连接联合骨折后,出现了侧错牙合。计算机断层扫描还发现了基突骨右翼、右颧弓、左髁旁突和下颌骨外侧体的骨折。垂直支骨折采用20孔3.5 mm SOP钢板进行修复,钢板轮廓为下颌骨的腹侧角。一个比例(1:4)的三维打印模型辅助术前和术中手术计划。在4周的复查中,母马感觉舒适,饮食状况良好。x线片显示上颌骨骨痂形成良好,下颌联合和支愈合。就在为期10周的复查之前,这匹小马患上了严重的小肠结肠炎,并被安乐死。结论SOP钢板的锁定功能为骨折愈合提供了足够的稳定性,无需使用锁定螺钉。三维打印模型在没有透视的情况下有助于复杂骨折的导航。