Vascular access for extracorporeal circulation. Resistance in double lumen cannulas.

ASAIO transactions Pub Date : 1991-07-01
C C Stroud, S L Meyer, M C Bawkon, H G Smith, M D Klein
{"title":"Vascular access for extracorporeal circulation. Resistance in double lumen cannulas.","authors":"C C Stroud,&nbsp;S L Meyer,&nbsp;M C Bawkon,&nbsp;H G Smith,&nbsp;M D Klein","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Double lumen catheters (DLCs) currently are being used for vascular access with extracorporeal circulation. Blood flow studies were done on various DLCs connected to a circuit made of polyvinyl chloride tubing. Sheep's blood was used with all catheters at flows of 200 and 400 ml/min. The inlet and outlet pressures were measured and resistances calculated. Modified versions of the Shiley and Kendall catheters, also were tested. In both catheters, resistance was reduced with the use of perfusion adaptors. Flow through catheters, with a diameter that exceeded the Luer fitting dimension, was compromised. The modified Shiley and unmodified Kendall catheters had the lowest resistance to flow, and they thus are best suited for extracorporeal circulation.</p>","PeriodicalId":77493,"journal":{"name":"ASAIO transactions","volume":"37 3","pages":"M418-9"},"PeriodicalIF":0.0000,"publicationDate":"1991-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ASAIO transactions","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Double lumen catheters (DLCs) currently are being used for vascular access with extracorporeal circulation. Blood flow studies were done on various DLCs connected to a circuit made of polyvinyl chloride tubing. Sheep's blood was used with all catheters at flows of 200 and 400 ml/min. The inlet and outlet pressures were measured and resistances calculated. Modified versions of the Shiley and Kendall catheters, also were tested. In both catheters, resistance was reduced with the use of perfusion adaptors. Flow through catheters, with a diameter that exceeded the Luer fitting dimension, was compromised. The modified Shiley and unmodified Kendall catheters had the lowest resistance to flow, and they thus are best suited for extracorporeal circulation.

分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
体外循环的血管通路。双腔插管阻力。
双腔导管(dlc)目前被用于体外循环血管通路。血流研究是在不同的dlc上进行的,dlc连接到一个由聚氯乙烯管制成的电路上。所有导管取羊血,流速分别为200和400 ml/min。测量了进口和出口压力,计算了阻力。改良版的希利导管和肯德尔导管也进行了测试。在两根导管中,使用灌注接头减少了阻力。通过导管的流量,其直径超过鲁尔拟合尺寸,受到损害。改良的希利导管和未改良的肯德尔导管具有最低的流动阻力,因此它们最适合体外循环。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Mechanism of dialysis-induced hypotension. Platelet preservation during cardiopulmonary bypass with iloprost and Duraflo-II heparin-coated surfaces. Peritoneal fluid kinetics during CAPD measured with intraperitoneal dextran 70. Influence of centrifugal blood pumps on the elasticity of erythrocytes. Reuse of "highly permeable" dialyzers with peroxyacetic acid as sole cleansing and disinfecting agent.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1