Polyvinyl chloride matrix membrane electrodes for manual and flow injection analysis of chloroquine in pharmaceutical preparations.

S S Hassan, M A Ahmed
{"title":"Polyvinyl chloride matrix membrane electrodes for manual and flow injection analysis of chloroquine in pharmaceutical preparations.","authors":"S S Hassan,&nbsp;M A Ahmed","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Two types of polyvinyl chloride (PVC) matrix membrane electrodes responsive to the antimalarial drug chloroquine have been constructed, electrochemically evaluated, compared and used in pharmaceutical analysis. Type 1 is the classic PVC model with chloroquine-tetraphenylborate (TPB) sensor; Type 2 is a coated silver disk without internal filling solution. Both electrode types exhibited rapid linear potentiometric response to the logarithmic concentration of diprotonated chloroquine cation in the 10(-1) - 10(-6)M range with calibration slopes 28-30 mV/concentration decade over the pH range 1.8-6.2. These electrodes were sensitive enough to permit determination of chloroquine phosphate at concentrations as low as 5 microgram/mL with good accuracy and precision. Determination of chloroquine in various pharmaceutical preparations using direct potentiometry and potentiometric titration with NaTPB gave an average recovery of 98.8% of the nominal values (SD 0.5%). The Type 2 electrode was also assessed in a flow-through sandwich cell for flow injection analysis. Results were compared with data obtained by the U.S. Pharmacopeia method.</p>","PeriodicalId":14752,"journal":{"name":"Journal - Association of Official Analytical Chemists","volume":"74 6","pages":"900-5"},"PeriodicalIF":0.0000,"publicationDate":"1991-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal - Association of Official Analytical Chemists","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Two types of polyvinyl chloride (PVC) matrix membrane electrodes responsive to the antimalarial drug chloroquine have been constructed, electrochemically evaluated, compared and used in pharmaceutical analysis. Type 1 is the classic PVC model with chloroquine-tetraphenylborate (TPB) sensor; Type 2 is a coated silver disk without internal filling solution. Both electrode types exhibited rapid linear potentiometric response to the logarithmic concentration of diprotonated chloroquine cation in the 10(-1) - 10(-6)M range with calibration slopes 28-30 mV/concentration decade over the pH range 1.8-6.2. These electrodes were sensitive enough to permit determination of chloroquine phosphate at concentrations as low as 5 microgram/mL with good accuracy and precision. Determination of chloroquine in various pharmaceutical preparations using direct potentiometry and potentiometric titration with NaTPB gave an average recovery of 98.8% of the nominal values (SD 0.5%). The Type 2 electrode was also assessed in a flow-through sandwich cell for flow injection analysis. Results were compared with data obtained by the U.S. Pharmacopeia method.

分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
用于药物制剂中氯喹手工和流动注射分析的聚氯乙烯基质膜电极。
构建了两种对抗疟药物氯喹有响应的聚氯乙烯(PVC)基质膜电极,并对其进行了电化学评价、比较,并将其用于药物分析。1型是带有氯喹-四苯基硼酸盐(TPB)传感器的经典PVC模型;类型2是没有内部填充溶液的涂层银盘。在10(-1)- 10(-6)M范围内,两种电极类型对双质子化氯喹阳离子的对数浓度均表现出快速的线性电位响应,在pH值1.8-6.2范围内,校准斜率为28-30 mV/浓度十年。这些电极足够灵敏,可以在低至5微克/毫升的浓度下测定磷酸氯喹,具有良好的准确性和精密度。采用直接电位法和硝酸甘油电位滴定法测定各种制剂中的氯喹,平均回收率为标称值的98.8% (SD为0.5%)。2型电极也在流动注射分析的流过夹层细胞中进行评估。结果与美国药典方法所得数据进行了比较。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Liquid chromatographic determination of paralytic shellfish poisons in shellfish after prechromatographic oxidation. Liquid chromatographic determination of paraquat and diquat in crops using a silica column with aqueous ionic mobile phase. Enzymatic determination of free glutamic acid in dried soups and in minced sausages: NMKL collaborative study. Separation and determination of diesel contaminants in various fish products by capillary gas chromatography. Monitoring aldehyde production during frying by reversed-phase liquid chromatography.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1