{"title":"Influence of Thermal Power Plants Equipment Structure on the Size of Sanitary Protection Zone by Noise Factor","authors":"V. Tupov, A. Taratorin","doi":"10.1109/REEPE49198.2020.9059202","DOIUrl":null,"url":null,"abstract":"Article analyzes the influence of the combined heat and power plant (CHP) equipment structure on the size of sanitary protection zone (SPZ) by noise factor. Analyze realized in relation to different climatic conditions. The differences between calculation of sanitary protection zone by noise factor and pollutants air emissions have been shown. The calculation results of semiempirical theory and calculations results by computer technology with different types and structure of operating equipment were compared. The conditions when the results of calculation of SPZ differ are shown. The results of climatic conditions influence on the width of sanitary protection zones are presented. Changes of width of SPZ for climatic conditions of Moscow are given. Obtained results allow to select noise reduction measures more accurate and cost-effective.","PeriodicalId":142369,"journal":{"name":"2020 International Youth Conference on Radio Electronics, Electrical and Power Engineering (REEPE)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 International Youth Conference on Radio Electronics, Electrical and Power Engineering (REEPE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/REEPE49198.2020.9059202","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4
Abstract
Article analyzes the influence of the combined heat and power plant (CHP) equipment structure on the size of sanitary protection zone (SPZ) by noise factor. Analyze realized in relation to different climatic conditions. The differences between calculation of sanitary protection zone by noise factor and pollutants air emissions have been shown. The calculation results of semiempirical theory and calculations results by computer technology with different types and structure of operating equipment were compared. The conditions when the results of calculation of SPZ differ are shown. The results of climatic conditions influence on the width of sanitary protection zones are presented. Changes of width of SPZ for climatic conditions of Moscow are given. Obtained results allow to select noise reduction measures more accurate and cost-effective.