A comparison study of MVDC and MVAC for deployment of distributed wind generations

Thai-Thanh Nguyen, H. Yoo, Hak-Man Kim
{"title":"A comparison study of MVDC and MVAC for deployment of distributed wind generations","authors":"Thai-Thanh Nguyen, H. Yoo, Hak-Man Kim","doi":"10.1109/ICSET.2016.7811770","DOIUrl":null,"url":null,"abstract":"Direct current (DC) connection of the large-scale wind generations with high voltage levels and long distance has been widely developed. Meanwhile, medium voltage direct current (MVDC) can also offer similar benefits compared to high voltage direct current connection of wind generations. This study presents a comparison study of MVDC and MVAC for the integration of distributed wind generations. The MVDC system is adopted from the IEEE 15-bus radial distribution system. The wind generators based on the doubly fed induction generators (DFIG) and those control schemes for the connection with MVDC grid are described. Several test cases such as loss of wind generator, loss of diesel generator, or fault are performed. Simulation model is implemented in MATLAB / Simulink environment.","PeriodicalId":164446,"journal":{"name":"2016 IEEE International Conference on Sustainable Energy Technologies (ICSET)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"13","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 IEEE International Conference on Sustainable Energy Technologies (ICSET)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICSET.2016.7811770","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 13

Abstract

Direct current (DC) connection of the large-scale wind generations with high voltage levels and long distance has been widely developed. Meanwhile, medium voltage direct current (MVDC) can also offer similar benefits compared to high voltage direct current connection of wind generations. This study presents a comparison study of MVDC and MVAC for the integration of distributed wind generations. The MVDC system is adopted from the IEEE 15-bus radial distribution system. The wind generators based on the doubly fed induction generators (DFIG) and those control schemes for the connection with MVDC grid are described. Several test cases such as loss of wind generator, loss of diesel generator, or fault are performed. Simulation model is implemented in MATLAB / Simulink environment.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
分布式风力发电配置中MVDC与MVAC的比较研究
大型高电压级长距离风力发电机组的直流连接得到了广泛的发展。同时,与风力发电机组的高压直流连接相比,中压直流(MVDC)也可以提供类似的好处。本文对分布式风力发电系统集成中的MVDC和MVAC进行了比较研究。MVDC系统采用IEEE 15总线径向配电系统。介绍了基于双馈感应发电机(DFIG)的风力发电机及其与MVDC并网的控制方案。进行了风力发电机失电、柴油发电机失电、故障等测试用例。仿真模型在MATLAB / Simulink环境下实现。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
LED lighting as energy management tool through correlation analysis of daily electricity demand and supply curve Toward building energy management: Electric analog modeling for thermal behavior simulation Using double Fed induction generator to enhance voltage stability and solving economic issue Modeling and analysis of an integrated AC-DC network under AC and DC faults Adaptive virtual impedance control scheme to eliminate reactive power sharing errors in islanded microgrid
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1