FDTD simulation of back-flashover at the transmission-line tower struck by lightning considering ground-wire corona

T. H. Thang, Y. Baba, N. Itamoto, V. Rakov
{"title":"FDTD simulation of back-flashover at the transmission-line tower struck by lightning considering ground-wire corona","authors":"T. H. Thang, Y. Baba, N. Itamoto, V. Rakov","doi":"10.1109/ICLP.2016.7791502","DOIUrl":null,"url":null,"abstract":"In this paper, we have simulated back-flashover at transmission line tower struck by lightning in the presence of corona emanated at the ground wire. In the simulations, three two-circuit 60-m high towers, separated by 400 m, with two overhead ground wires, and six phase conductors (two three-phase circuits) are employed. A simplified (engineering) model of corona discharge is applied to the analysis of transient voltages across insulators of transmission line. Back-flashover is assumed to occur at upper-, middle-, or lower phase. On the basis of computed results, the effect of corona space charge emanated from ground wires on transient voltages across insulators in the presence of back-flashover is discussed.","PeriodicalId":373744,"journal":{"name":"2016 33rd International Conference on Lightning Protection (ICLP)","volume":"141 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 33rd International Conference on Lightning Protection (ICLP)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICLP.2016.7791502","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

In this paper, we have simulated back-flashover at transmission line tower struck by lightning in the presence of corona emanated at the ground wire. In the simulations, three two-circuit 60-m high towers, separated by 400 m, with two overhead ground wires, and six phase conductors (two three-phase circuits) are employed. A simplified (engineering) model of corona discharge is applied to the analysis of transient voltages across insulators of transmission line. Back-flashover is assumed to occur at upper-, middle-, or lower phase. On the basis of computed results, the effect of corona space charge emanated from ground wires on transient voltages across insulators in the presence of back-flashover is discussed.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
考虑地线电晕的输电线路塔雷击反闪络时域有限差分仿真
本文模拟了在接地线产生电晕的情况下,输电铁塔遭雷击后的反闪络现象。在模拟中,三个60米高的双线塔,相隔400米,有两个架空地线,和六个相导体(两个三相电路)。将电晕放电的简化(工程)模型应用于输电线路绝缘子间暂态电压的分析。反闪络假定发生在上相、中相或下相。在计算结果的基础上,讨论了在反闪络存在时,接地线发射的电晕空间电荷对绝缘子间瞬态电压的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Experimental and theoretical evaluation of aluminium deflection due to lightning strikes Degradation characteristics on MOV of surge arrester used for 6.6kV power distribution line Lightning protection of a temporary structure in open area Lightning performance of EHV and UHV overhead transmission Lines in China southern power grid Research of influence pattern of lightning current on impulse characteristic of ground device for pole and tower
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1