Eighteen-pulse rectifiers for harmonic mitigation

S. Kocman, V. Kolář, T. Trung Vo
{"title":"Eighteen-pulse rectifiers for harmonic mitigation","authors":"S. Kocman, V. Kolář, T. Trung Vo","doi":"10.1109/ICHQP.2010.5625409","DOIUrl":null,"url":null,"abstract":"Multi-pulses rectifiers are one of the technical solutions for harmonic mitigation in AC adjustable speed drives. 12-pulse, 18-pulse and 24-pulse rectifier topologies are used in various technical applications. The paper presents results from experimental measurements and results from simulations for two topologies of the eighteen-pulse rectifiers: with Dy1z1+200z1−200 and with Dd0diii0+200diii0−200 transformers. To simulate the behavior of the both eighteen-pulse rectifiers under various levels of voltage distortion a program written in FORTRAN in EMTP-ATP simulation program has been developed. Both experimental measurements and simulations demonstrate their high harmonic mitigation effectiveness. A comparison of the eighteen-pulse rectifiers with some other techniques for harmonic mitigation is also shown in the paper.","PeriodicalId":180078,"journal":{"name":"Proceedings of 14th International Conference on Harmonics and Quality of Power - ICHQP 2010","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2010-11-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of 14th International Conference on Harmonics and Quality of Power - ICHQP 2010","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICHQP.2010.5625409","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

Abstract

Multi-pulses rectifiers are one of the technical solutions for harmonic mitigation in AC adjustable speed drives. 12-pulse, 18-pulse and 24-pulse rectifier topologies are used in various technical applications. The paper presents results from experimental measurements and results from simulations for two topologies of the eighteen-pulse rectifiers: with Dy1z1+200z1−200 and with Dd0diii0+200diii0−200 transformers. To simulate the behavior of the both eighteen-pulse rectifiers under various levels of voltage distortion a program written in FORTRAN in EMTP-ATP simulation program has been developed. Both experimental measurements and simulations demonstrate their high harmonic mitigation effectiveness. A comparison of the eighteen-pulse rectifiers with some other techniques for harmonic mitigation is also shown in the paper.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
18脉冲整流器用于谐波缓解
多脉冲整流器是交流调速传动中谐波抑制的技术解决方案之一。12脉冲,18脉冲和24脉冲整流器拓扑结构用于各种技术应用。本文介绍了18脉冲整流器的两种拓扑结构:Dy1z1+200z1−200和Dd0diii0+200diii0−200变压器的实验测量和仿真结果。为了模拟这两种18脉冲整流器在不同电压畸变水平下的行为,在EMTP-ATP仿真程序中编写了用FORTRAN编写的程序。实验测量和仿真结果均证明了该方法具有较高的谐波抑制效果。本文还比较了十八脉冲整流器与其他谐波抑制技术的优缺点。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Harmonic domain modeling of transformer nonlinear characteristic with piece-wise approximation Classification of Power Quality disturbances using the iterative Hilbert Huang Transform The problems of centralized decrease of harmonic voltages in the HV networks with distributed nonlinear loads Elimination of harmonics using multi-pulse rectifiers Power quality in public lighting systems
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1