Detecting insulation condition changes of inverter Fed AC machines based on two current sensors and indirect phase step excitation

C. Zoeller, M. Vogelsberger, H. Wiedner, J. Riefel, T. Wolbank
{"title":"Detecting insulation condition changes of inverter Fed AC machines based on two current sensors and indirect phase step excitation","authors":"C. Zoeller, M. Vogelsberger, H. Wiedner, J. Riefel, T. Wolbank","doi":"10.1109/SPEEDAM.2014.6871952","DOIUrl":null,"url":null,"abstract":"A high number of breakdowns of adjustable speed drives (ASD) is caused by a fault of the machine, especially stator related insulation faults frequently occur. The evaluation of the insulation condition is possible with the current sensor signals only. The analyses of the transient part of the current response give evidence if a change in the insulation system occurred. The degradation of the insulation state is noticeable through a capacitive change, which influences the high frequency behavior of the machine and as a consequence the transient part of the current signal. The proposed method is capable to detect insulation degradation through analyzing the transient current response of the sensors already used for the control of the machine. Additionally, the profitable capital expenditure demands the design with minimal number of components. To reduce the costs only two current sensors are available. The non-measured transient phase current response can be reconstructed by a special excitation sequence and signal processing without significant deterioration of sensitivity.","PeriodicalId":344918,"journal":{"name":"2014 International Symposium on Power Electronics, Electrical Drives, Automation and Motion","volume":"29 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-06-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 International Symposium on Power Electronics, Electrical Drives, Automation and Motion","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SPEEDAM.2014.6871952","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

A high number of breakdowns of adjustable speed drives (ASD) is caused by a fault of the machine, especially stator related insulation faults frequently occur. The evaluation of the insulation condition is possible with the current sensor signals only. The analyses of the transient part of the current response give evidence if a change in the insulation system occurred. The degradation of the insulation state is noticeable through a capacitive change, which influences the high frequency behavior of the machine and as a consequence the transient part of the current signal. The proposed method is capable to detect insulation degradation through analyzing the transient current response of the sensors already used for the control of the machine. Additionally, the profitable capital expenditure demands the design with minimal number of components. To reduce the costs only two current sensors are available. The non-measured transient phase current response can be reconstructed by a special excitation sequence and signal processing without significant deterioration of sensitivity.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于双电流传感器和间接相位阶跃励磁的逆变式Fed交流电机绝缘状态变化检测
调速变频器的大量故障是由电机自身故障引起的,特别是定子相关绝缘故障频繁发生。仅用电流传感器信号就可以对绝缘状况进行评估。当绝缘系统发生变化时,对电流响应的暂态部分的分析给出了证据。通过电容变化,绝缘状态的退化是明显的,这会影响机器的高频行为,从而影响电流信号的瞬态部分。所提出的方法能够通过分析已用于机器控制的传感器的瞬态电流响应来检测绝缘退化。此外,有利可图的资本支出要求设计具有最少数量的组件。为了降低成本,只有两个电流传感器可用。通过特殊的激励序列和信号处理,可以重建未测量的瞬态相电流响应,而不会显著降低灵敏度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
A wireless controlled circuit for PV panel disconnection in case of fire Voltage stabilization in weak grids by high power charging stations Concepts for an integration of quick charging stations in weak power grids Some lab experiments on the control of an aircraft electrical landing gear Controller Hardware-In-the-Loop validation of a magnetic core saturation algorithm for fault ride-through evaluations
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1