Influence of Distributed Generation on Power Frequency Overvoltage Characteristics of Transformer Neutral Point

Changhao He, Rui Qin, Baojun Xu, Yuyin Zhan, Haifeng Li
{"title":"Influence of Distributed Generation on Power Frequency Overvoltage Characteristics of Transformer Neutral Point","authors":"Changhao He, Rui Qin, Baojun Xu, Yuyin Zhan, Haifeng Li","doi":"10.1109/ICPES56491.2022.10073131","DOIUrl":null,"url":null,"abstract":"Distributed generation (DG) will bring various problems to the relay protection and automation of distribution network, which may also lead to serious consequences of the ungrounded transformer neutral point overvoltage. This paper analyzes the mechanism of power frequency overvoltage at the ungrounded transformer neutral point under single-phase grounding fault. Based on it, this paper studies the influence of DG on neutral point overvoltage after 110kV line fault in detail. Considering that there are rotational DGs and inverter-interfaced DGs (IIDGs) under different control modes, test results show that PQ-controlled DG makes the transformer neutral point voltage exceeds its rated value easiest, and it also has the greatest insulation threat to neutral point overvoltage.","PeriodicalId":425438,"journal":{"name":"2022 12th International Conference on Power and Energy Systems (ICPES)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-12-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 12th International Conference on Power and Energy Systems (ICPES)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICPES56491.2022.10073131","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Distributed generation (DG) will bring various problems to the relay protection and automation of distribution network, which may also lead to serious consequences of the ungrounded transformer neutral point overvoltage. This paper analyzes the mechanism of power frequency overvoltage at the ungrounded transformer neutral point under single-phase grounding fault. Based on it, this paper studies the influence of DG on neutral point overvoltage after 110kV line fault in detail. Considering that there are rotational DGs and inverter-interfaced DGs (IIDGs) under different control modes, test results show that PQ-controlled DG makes the transformer neutral point voltage exceeds its rated value easiest, and it also has the greatest insulation threat to neutral point overvoltage.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
分布式发电对变压器中性点工频过电压特性的影响
分布式发电会给配电网的继电保护和自动化带来各种问题,也可能导致变压器中性点不接地过电压的严重后果。分析了单相接地故障下不接地变压器中性点工频过电压产生的机理。在此基础上,详细研究了110kV线路故障后DG对中性点过电压的影响。考虑到不同控制方式下存在旋转DG和逆变器接口DG (iidg),测试结果表明,pq控制DG最容易使变压器中性点电压超过额定值,对中性点过电压的绝缘威胁也最大。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Optimal Scheduling Method for the Distribution Network Integrated with Multi-Energy Systems Considering Flexible Regulation Ability Methods for the Tower Fatigue Loads to Cumulative Based on Wind Direction Probabilistic Application of Thermal Resistance Dynamic Characteristics on High-Voltage Cable Ampacity Based on Field Circuit Coupling Method Residential Load Forecasting Based on CNN-LSTM and Non-uniform Quantization Application Scenario Analysis and Prospect of Electricity Emissions Factor
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1