N. Prindeze, H. Hoffman, B. Carney, L. Moffatt, M. Loew, J. Shupp
{"title":"Evaluation of the variable depth resolution of active dynamic thermography on human skin","authors":"N. Prindeze, H. Hoffman, B. Carney, L. Moffatt, M. Loew, J. Shupp","doi":"10.1117/12.2180807","DOIUrl":null,"url":null,"abstract":"Active dynamic thermography (ADT) is an imaging technique capable of characterizing the non-homogenous thermal conductance of damaged tissues. The purpose of this study was to determine optimal stimulation parameters and quantify the optical resolution of ADT through various depths of human skin. Excised tissue from plastic surgery operations was collected immediately following excision. A total of 12 thin to thick split-thickness grafts were harvested from 3 patients. Grafts were placed on top of a 3D printed resolution chart and thermal stimulation was applied from a 300W halogen lamp array for between 0.5-10 seconds to determine optimal parameters. Video was captured with a thermal camera, and analysis was performed by reconstructing an image from thermal gradients. In this study ADT resolved 0.445±0 lp/mm at a depth of 0.010”, 0.356±0.048 lp/mm at a depth of 0.015”, 0.334±0.027 lp/mm at a depth of 0.020” and 0.265±0.022 lp/mm at a depth of 0.025”. The stimulus energy required for maximum resolution at each depth was 3- 4s, 8s, 12s and 12s respectively. ADT is a sensitive technique for imaging dermal structure, capable of resolving detail as fine as 1124 μm, 1427 μm, 1502 μm and 1893 μm in thin to thick split-thickness skin grafts respectively. This study has characterized a correlation between stimulus input and maximal resolution at differing depths of skin. It has also defined the functional imaging depth of ADT to below the sub-cutis, well below conventional spectrophotometric techniques.","PeriodicalId":307847,"journal":{"name":"Biophotonics South America","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-06-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biophotonics South America","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1117/12.2180807","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1
Abstract
Active dynamic thermography (ADT) is an imaging technique capable of characterizing the non-homogenous thermal conductance of damaged tissues. The purpose of this study was to determine optimal stimulation parameters and quantify the optical resolution of ADT through various depths of human skin. Excised tissue from plastic surgery operations was collected immediately following excision. A total of 12 thin to thick split-thickness grafts were harvested from 3 patients. Grafts were placed on top of a 3D printed resolution chart and thermal stimulation was applied from a 300W halogen lamp array for between 0.5-10 seconds to determine optimal parameters. Video was captured with a thermal camera, and analysis was performed by reconstructing an image from thermal gradients. In this study ADT resolved 0.445±0 lp/mm at a depth of 0.010”, 0.356±0.048 lp/mm at a depth of 0.015”, 0.334±0.027 lp/mm at a depth of 0.020” and 0.265±0.022 lp/mm at a depth of 0.025”. The stimulus energy required for maximum resolution at each depth was 3- 4s, 8s, 12s and 12s respectively. ADT is a sensitive technique for imaging dermal structure, capable of resolving detail as fine as 1124 μm, 1427 μm, 1502 μm and 1893 μm in thin to thick split-thickness skin grafts respectively. This study has characterized a correlation between stimulus input and maximal resolution at differing depths of skin. It has also defined the functional imaging depth of ADT to below the sub-cutis, well below conventional spectrophotometric techniques.